PARAMETERS | PARMS parameters <<=> numbers (numbers)> <<,> parameters <<=> numbers (numbers)> …>;
The PARAMETERS statement defines parameters that are useful in the modeling. You can specify more than one PARAMETERS statement.
The three main uses of the PARAMETERS statement are as follows:
Define independent parameters that are not specified in your model. In some modeling situations, it is more convenient (practically or conceptually) to define the model parameters as functions of these independent parameters. PROC CALIS computes the estimates and their standard errors for these independent parameters.
Define dependent parameters of interest. These dependent parameters are then defined as functions of the model parameters in the SAS programming statements. PROC CALIS computes the estimates and their standard errors for these dependent parameters.
Provide initial values for the free parameters in the model if they have not been specified in the model specification statements.
For example, the following statements illustrate the three main uses of the PARAMETERS statement:
proc calis; path V1 <=== V2 = b1, V1 <=== V3 = b2, V2 <=== V4 = b3 (0.9), V3 <=== V5 = b4; parameters a1 (0.1) a2 (0.2) b3 (0.3) b4 (0.4) b5; b1 = -a1 / a2; b2 = 1 / a2; b5 = b3 - b4; run;
In the PARAMETERS statement, you specify five parameters that take different roles in the modeling. Parameters a1
and a2
are independent parameters that are not specified in the PATH statement, which specifies four paths with four parameters
for the path coefficients b1
, b2
, b3
, and b4
. The two SAS programming statements immediately after the PARAMETERS statement define parameters b1
and b2
as functions of parameters a1
and a2
. Because a1
and a2
appear only on the right side of the programming statements, they are independent parameters of the model. In addition, b1
and b2
are dependent parameters because they appear on the left side of the first two programming statements. Independent parameters
a1
and a2
are provided with initial values 0.1 and 0.2, respectively, in the PARAMETERS statement. Because the initial values these
two independent parameters are used, dependent parameters b1
and b2
are also initialized with values –0.5 and 5, respectively.
Parameters b3
and b4
appear in both the PATH and PARAMETERS statements. Because these two parameters are already specified in the PATH statement,
their initial values might have been defined in the model. For example, parameter b3
in the PATH statement has an initial value of 0.9. This initial value is not replaced by the initial value of 0.3 specified in the PARAMETERS statement. However, because you do not specify an initial
value for parameter b4
in the PATH statement, the initial value of 0.4 specified in the PARAMETERS statement is used. In general, the initial values
that are specified in the PARAMETERS statement do not replace the initial values that have already been specified for the
same parameters in the model.
Parameter b5
in the PARAMETERS statement is a dependent parameter, which is defined as the difference between the model parameters b3
and b4
in the last SAS programming statement. No initial value for this dependent parameter is provided (nor is it needed). By definition,
dependent parameters are functions of other parameters, so their initial values are computed. In this example, parameter b5
takes an initial value of 0.5, the difference between the initial values of b3
and b4
.
It is not necessary to provide initial values for the parameters in the PARAMETERS statement. For the independent parameters without initial values specified, PROC CALIS generates the initial values from the START= value in the PROC CALIS statement. The default START= value is 0.5. If you specify the RANDOM= option in the PROC CALIS statement, random numbers are generated for the initial values of the independent parameters. For the dependent parameters, PROC CALIS computes the initial values by using the SAS programming statements.
In general, the number of parameters and the number of initial values do not have to match. When you specify fewer initial values than parameter names, PROC CALIS either generates or computes the initial values. When you specify more values than parameter names, the extra values are ignored.
For example, consider the following statements:
parameters c1 c2 c3 c4 (0.2 0.3 0.4); parameters d1 d2 d3 d4 (0.1 0.2 0.3 0.4 0.5); run;
The first PARAMETERS statement has a shorter initial value list than the parameter list. The initial values 0.2, 0.3, and
0.4 are assigned to c2
, c3
, and c4
, respectively. PROC CALIS generates the initial value for c1
. The second PARAMETERS statement has a longer initial value list than the parameter list. The initial values 0.1, 0.2, 0.3,
and 0.4 are assigned to d1
, d2
, d3
, and d4
, respectively. The extra initial value 0.5 is ignored.
When the lengths of the parameter list and the initial value list match, you can use an equal sign between the lists freely
without affecting the assignments of the initial values. For example, each of the following PARAMETERS statements assigns
the initial values alpha
=0.5 and beta
=–0.5:
parameters alfa 0.5 beta -0.5; parameters alfa = 0.5 beta = -0.5; parameters alfa (0.5) beta (-0.5); parameters alfa = (0.5) beta = (-0.5); parameters alfa beta 0.5 -0.5; parameters alfa beta = 0.5 -0.5; parameters alfa beta (0.5 -0.5); parameters alfa beta = (0.5 -0.5);
However, when the parameter list is longer than the initial value list, the equal sign affects the assignments of the initial
values. For example, the following statement assigns the initial values to the last three parameters, c2
, c3
, and c4
:
parameters c1 c2 c3 c4 (0.2 0.3 0.4);
But with an equal sign between the lists, the following statement assigns the initial values to the first three parameters,
c1
, c2
, and c3
:
parameters c1 c2 c3 c4 = (0.2 0.3 0.4);
To make initial value assignments less ambiguous, you can use commas to separate parameter lists. For example, the following
statement clearly assigns the initial values to c2
, c3
, and c4
:
parameters c1, c2 c3 c4 (0.2 0.3 0.4);
This specification is equivalent to the same specification without the comma. But the specification is certainly less ambiguous with the comma.
Proper grouping of the parameter and initial value lists with the use of commas helps make the specification in the PARAMETERS statement clear. For example, consider the following specification:
parameters c1 c2 c3 c4 = (0.1 0.2 0.3) c5 c6 (0.6);
Initial values 0.1, 0.2, 0.3, and 0.6 are assigned to parameters c1
, c2
, c3
, and c6
, respectively. Initial values for other parameters are either generated or computed by PROC CALIS. A much better practice
is to use the following equivalent specification:
parameters c1 c2 c3 (0.1 0.2 0.3), c4 c5, c6 (0.6);
Matching the number of parameters and the number of initial values (if provided) in entries separated by commas in the PARAMETERS statement is highly recommended. It reduces ambiguities and makes your code more interpretable.
It is important to notice that PROC CALIS does not have better alternatives to generate initial values (such as those for setting the initial values of the model parameters) for the independent parameters specified in the PARAMETERS statement other than using either the START= value or random values generated by using the RANDOM= option. These ad hoc initial values are arbitrary and might not always lead to converged solutions. Therefore, you should try to provide good initial values for those independent parameters that are defined only in the PARAMETERS statement.
Do not confuse the PARAMETERS statement with the VAR statement. While you specify the parameters of the model in the PARAMETERS statement, you specify analysis variables in the VAR statement. See the VAR statement for more details.
Caution: The OUTMODEL= and OUTRAM= data sets do not contain any information about the PARAMETERS statement or the SAS programming statements.