The following sections provide information about the families of parametric distributions that you can fit with the HISTOGRAM statement. Properties of these distributions are discussed by Johnson, Kotz, and Balakrishnan (1994, 1995).
The fitted density function is
where 
 and 
            
 lower threshold parameter (lower endpoint parameter) 
                     
 scale parameter 
 
                     
 shape parameter 
 
                     
 shape parameter 
 
                     
 width of histogram interval 
                     
 vertical scaling factor 
                     
and
![\[  v = \left\{  \begin{array}{ll} n &  \mbox{the sample size, for VSCALE=COUNT} \\ 100 &  \mbox{for VSCALE=PERCENT} \\ 1 &  \mbox{for VSCALE=PROPORTION} \end{array} \right.  \]](images/procstat_univariate0313.png)
Note: This notation is consistent with that of other distributions that you can fit with the HISTOGRAM statement. However, many texts, including Johnson, Kotz, and Balakrishnan (1995), write the beta density function as
The two parameterizations are related as follows:
 
                     
 
                     
 
                     
 
                     
The range of the beta distribution is bounded below by a threshold parameter 
 and above by 
. If you specify a fitted beta curve by using the BETA option, 
 must be less than the minimum data value and 
 must be greater than the maximum data value. You can specify 
 and 
 with the THETA= and SIGMA= beta-options in parentheses after the keyword BETA. By default, 
 and 
. If you specify THETA=EST and SIGMA=EST, maximum likelihood estimates are computed for 
 and 
. However, three- and four-parameter maximum likelihood estimation does not always converge. 
            
In addition, you can specify 
 and 
 with the ALPHA= and BETA= beta-options, respectively. By default, the procedure calculates maximum likelihood estimates for 
 and 
. For example, to fit a beta density curve to a set of data bounded below by 32 and above by 212 with maximum likelihood estimates
               for 
 and 
, use the following statement: 
            
histogram Length / beta(theta=32 sigma=180);
The beta distributions are also referred to as Pearson Type I or II distributions. These include the power function distribution
               (
), the arc sine distribution (
), and the generalized arc sine distributions (
, 
). 
            
You can use the DATA step function QUANTILE to compute beta quantiles and the DATA step function CDF to compute beta probabilities.
The fitted density function is
where
 threshold parameter 
                     
 scale parameter 
 
                     
 width of histogram interval 
                     
 vertical scaling factor 
                     
and
![\[  v = \left\{  \begin{array}{ll} n &  \mbox{the sample size, for VSCALE=COUNT} \\ 100 &  \mbox{for VSCALE=PERCENT} \\ 1 &  \mbox{for VSCALE=PROPORTION} \end{array} \right.  \]](images/procstat_univariate0313.png)
The threshold parameter 
 must be less than or equal to the minimum data value. You can specify 
 with the THRESHOLD= exponential-option. By default, 
. If you specify THETA=EST, a maximum likelihood estimate is computed for 
. In addition, you can specify 
 with the SCALE= exponential-option. By default, the procedure calculates a maximum likelihood estimate for 
. Note that some authors define the scale parameter as 
. 
            
The exponential distribution is a special case of both the gamma distribution (with 
) and the Weibull distribution (with 
). A related distribution is the extreme value distribution. If 
 has an exponential distribution, then 
 has an extreme value distribution. 
            
You can use the DATA step function QUANTILE to compute exponential quantiles and the DATA step function CDF to compute exponential probabilities.
The fitted density function is
where
 threshold parameter 
                     
 scale parameter 
 
                     
 shape parameter 
 
                     
 width of histogram interval 
                     
 vertical scaling factor 
                     
and
![\[  v = \left\{  \begin{array}{ll} n &  \mbox{the sample size, for VSCALE=COUNT} \\ 100 &  \mbox{for VSCALE=PERCENT} \\ 1 &  \mbox{for VSCALE=PROPORTION} \end{array} \right.  \]](images/procstat_univariate0313.png)
The threshold parameter 
 must be less than the minimum data value. You can specify 
 with the THRESHOLD= gamma-option. By default, 
. If you specify THETA=EST, a maximum likelihood estimate is computed for 
. In addition, you can specify 
 and 
 with the SCALE= and ALPHA= gamma-options. By default, the procedure calculates maximum likelihood estimates for 
 and 
. 
            
The gamma distributions are also referred to as Pearson Type III distributions, and they include the chi-square, exponential, and Erlang distributions. The probability density function for the chi-square distribution is
Notice that this is a gamma distribution with 
, 
, and 
. The exponential distribution is a gamma distribution with 
, and the Erlang distribution is a gamma distribution with 
 being a positive integer. A related distribution is the Rayleigh distribution. If 
 where the 
’s are independent 
 variables, then 
 is distributed with a 
 distribution having a probability density function of 
            
If 
, the preceding distribution is referred to as the Rayleigh distribution. 
            
You can use the DATA step function QUANTILE to compute gamma quantiles and the DATA step function CDF to compute gamma probabilities.
The fitted density function is
where
 location parameter 
                     
 scale parameter 
 
                     
 width of histogram interval 
                     
 vertical scaling factor 
                     
and
![\[  v = \left\{  \begin{array}{ll} n &  \mbox{the sample size, for VSCALE=COUNT} \\ 100 &  \mbox{for VSCALE=PERCENT} \\ 1 &  \mbox{for VSCALE=PROPORTION} \end{array} \right.  \]](images/procstat_univariate0313.png)
You can specify 
 and 
 with the MU= and SIGMA= Gumbel-options, respectively. By default, the procedure calculates maximum likelihood estimates for these parameters. 
            
Note: The Gumbel distribution is also referred to as Type 1 extreme value distribution.
               Note: The random variable 
 has Gumbel (Type 1 extreme value) distribution if and only if 
 has Weibull distribution and 
 has standard exponential distribution. 
            
The fitted density function is
where
 location parameter 
 
                     
 shape parameter 
 
                     
 width of histogram interval 
                     
 vertical scaling factor 
                     
and
![\[  v = \left\{  \begin{array}{ll} n &  \mbox{the sample size, for VSCALE=COUNT} \\ 100 &  \mbox{for VSCALE=PERCENT} \\ 1 &  \mbox{for VSCALE=PROPORTION} \end{array} \right.  \]](images/procstat_univariate0313.png)
The location parameter 
 has to be greater then zero. You can specify 
 with the MU= iGauss-option. In addition, you can specify shape parameter 
 with LAMBDA= iGauss-option. By default, the procedure calculates maximum likelihood estimates for 
 and 
. 
            
               Note: The special case where 
 and 
 corresponds to the Wald distribution. 
            
You can use the DATA step function QUANTILE to compute inverse Gaussian quantiles and the DATA step function CDF to compute inverse Gaussian probabilities.
The fitted density function is
where
 threshold parameter 
                     
 scale parameter 
 
                     
 shape parameter 
 
                     
 width of histogram interval 
                     
 vertical scaling factor 
                     
and
![\[  v = \left\{  \begin{array}{ll} n &  \mbox{the sample size, for VSCALE=COUNT} \\ 100 &  \mbox{for VSCALE=PERCENT} \\ 1 &  \mbox{for VSCALE=PROPORTION} \end{array} \right.  \]](images/procstat_univariate0313.png)
The threshold parameter 
 must be less than the minimum data value. You can specify 
 with the THRESHOLD= lognormal-option. By default, 
. If you specify THETA=EST, a maximum likelihood estimate is computed for 
. You can specify 
 and 
 with the SCALE= and SHAPE= lognormal-options, respectively. By default, the procedure calculates maximum likelihood estimates for these parameters. 
            
               Note: The lognormal distribution is also referred to as the 
 distribution in the Johnson system of distributions. 
            
               Note: This book uses 
 to denote the shape parameter of the lognormal distribution, whereas 
 is used to denote the scale parameter of the other distributions. The use of 
 to denote the lognormal shape parameter is based on the fact that 
 has a standard normal distribution if 
 is lognormally distributed. Based on this relationship, you can use the DATA step function PROBIT to compute lognormal quantiles
               and the DATA step function PROBNORM to compute probabilities. 
            
The fitted density function is
where
 mean 
                     
 standard deviation 
 
                     
 width of histogram interval 
                     
 vertical scaling factor 
                     
and
![\[  v = \left\{  \begin{array}{ll} n &  \mbox{the sample size, for VSCALE=COUNT} \\ 100 &  \mbox{for VSCALE=PERCENT} \\ 1 &  \mbox{for VSCALE=PROPORTION} \end{array} \right.  \]](images/procstat_univariate0313.png)
You can specify 
 and 
 with the MU= and SIGMA= normal-options, respectively. By default, the procedure estimates 
 with the sample mean and 
 with the sample standard deviation. 
            
You can use the DATA step function QUANTILE to compute beta quantiles and the DATA step function CDF to compute normal probabilities.
               Note: The normal distribution is also referred to as the 
 distribution in the Johnson system of distributions. 
            
The fitted density function is
where
 threshold parameter 
                     
 shape parameter 
                     
 shape parameter 
 
                     
 width of histogram interval 
                     
 vertical scaling factor 
                     
and
![\[  v = \left\{  \begin{array}{ll} n &  \mbox{the sample size, for VSCALE=COUNT} \\ 100 &  \mbox{for VSCALE=PERCENT} \\ 1 &  \mbox{for VSCALE=PROPORTION} \end{array} \right.  \]](images/procstat_univariate0313.png)
The support of the distribution is 
 for 
 and 
 for 
. 
            
               Note: Special cases of Pareto distribution with 
 and 
 correspond respectively to the exponential distribution with mean 
 and uniform distribution on the interval 
. 
            
The threshold parameter 
 must be less than the minimum data value. You can specify 
 with the THETA= Pareto-option. By default, 
. You can also specify 
 and 
 with the ALPHA= and SIGMA= Pareto-options,respectively. By default, the procedure calculates maximum likelihood estimates for these parameters. 
            
               Note: Maximum likelihood estimation of the parameters works well if 
, but not otherwise. In this case the estimators are asymptotically normal and asymptotically efficient. The asymptotic normal
               distribution of the maximum likelihood estimates has mean 
 and variance-covariance matrix 
            
Note: If no local minimum found in the space
there is no maximum likelihood estimator. More details on how to find maximum likelihood estimators and suggested algorithm can be found in Grimshaw(1993).
The fitted density function is
where
 lower threshold parameter (lower endpoint parameter) 
                     
 scale parameter 
 
                     
 shape parameter 
 
                     
 width of histogram interval 
                     
 vertical scaling factor 
                     
and
![\[  v = \left\{  \begin{array}{ll} n &  \mbox{the sample size, for VSCALE=COUNT} \\ 100 &  \mbox{for VSCALE=PERCENT} \\ 1 &  \mbox{for VSCALE=PROPORTION} \end{array} \right.  \]](images/procstat_univariate0313.png)
Note: This notation is consistent with that of other distributions that you can fit with the HISTOGRAM statement. However, many texts, including Johnson, Kotz, and Balakrishnan (1995), write the density function of power function distribution as
The two parameterizations are related as follows:
 
                     
 
                     
 
                     
Note: The family of power function distributions is subclass of beta distribution with density function
where 
 with parameter 
. Therefore, all properties and estimation procedures of beta distribution apply. 
            
The range of the power function distribution is bounded below by a threshold parameter 
 and above by 
. If you specify a fitted power function curve by using the POWER option, 
 must be less than the minimum data value and 
 must be greater than the maximum data value. You can specify 
 and 
 with the THETA= and SIGMA= power-options in parentheses after the keyword POWER. By default, 
 and 
. If you specify THETA=EST and SIGMA=EST, maximum likelihood estimates are computed for 
 and 
. However, three-parameter maximum likelihood estimation does not always converge. 
            
In addition, you can specify 
 with the ALPHA= power-option. By default, the procedure calculates maximum likelihood estimate for 
. For example, to fit a power function density curve to a set of data bounded below by 32 and above by 212 with maximum likelihood
               estimate for 
, use the following statement: 
            
histogram Length / power(theta=32 sigma=180);
The fitted density function is
where
 lower threshold parameter (lower endpoint parameter) 
                     
 scale parameter 
 
                     
 width of histogram interval 
                     
 vertical scaling factor 
                     
and
![\[  v = \left\{  \begin{array}{ll} n &  \mbox{the sample size, for VSCALE=COUNT} \\ 100 &  \mbox{for VSCALE=PERCENT} \\ 1 &  \mbox{for VSCALE=PROPORTION} \end{array} \right.  \]](images/procstat_univariate0313.png)
Note: The Rayleigh distribution is Weibull distribution with density function
 and with shape parameter 
 and scale parameter 
. 
            
The threshold parameter 
 must be less than the minimum data value. You can specify 
 with the THETA= Rayleigh-option. By default, 
. In addition you can specify 
 with the SIGMA= Rayleigh-option. By default, the procedure calculates maximum likelihood estimate for 
. 
            
For example, to fit a Rayleigh density curve to a set of data bounded below by 32 with maximum likelihood estimate for 
, use the following statement: 
            
histogram Length / rayleigh(theta=32);
The fitted density function is
![\[  p(x) = \left\{  \begin{array}{ll} \frac{\delta hv}{\sigma \sqrt {2\pi } } \left[ \left( \frac{x - \theta }{\sigma } \right) \left( 1 - \frac{x - \theta }{\sigma } \right) \right]^{-1} \times & \\ \exp \left[ -\frac{1}{2} \left( \gamma + \delta \log ( \frac{x - \theta }{\theta + \sigma -x} ) \right)^2 \right] &  \mbox{for $ \theta < x < \theta + \sigma $} \\ 0 &  \mbox{for $ x \leq \theta $ or $ x \geq \theta + \sigma $} \end{array} \right.  \]](images/procstat_univariate0370.png)
where
 threshold parameter 
 
                     
 scale parameter 
 
                     
 shape parameter 
 
                     
 shape parameter 
 
                     
 width of histogram interval 
                     
 vertical scaling factor 
                     
and
![\[  v = \left\{  \begin{array}{ll} n &  \mbox{the sample size, for VSCALE=COUNT} \\ 100 &  \mbox{for VSCALE=PERCENT} \\ 1 &  \mbox{for VSCALE=PROPORTION} \end{array} \right.  \]](images/procstat_univariate0313.png)
The 
 distribution is bounded below by the parameter 
 and above by the value 
. The parameter 
 must be less than the minimum data value. You can specify 
 with the THETA= 
-option, or you can request that 
 be estimated with the THETA = EST 
-option. The default value for 
 is zero. The sum 
 must be greater than the maximum data value. The default value for 
 is one. You can specify 
 with the SIGMA= 
-option, or you can request that 
 be estimated with the SIGMA = EST 
-option. 
            
By default, the method of percentiles given by Slifker and Shapiro (1980) is used to estimate the parameters. This method is based on four data percentiles, denoted by 
, 
, 
, and 
, which correspond to the four equally spaced percentiles of a standard normal distribution, denoted by 
, 
, 
, and 
, under the transformation 
            
The default value of 
 is 0.524. The results of the fit are dependent on the choice of 
, and you can specify other values with the FITINTERVAL= option (specified in parentheses after the SB option). If you use
               the method of percentiles, you should select a value of 
 that corresponds to percentiles which are critical to your application. 
            
The following values are computed from the data percentiles:
It was demonstrated by Slifker and Shapiro (1980) that
![\[  \begin{array}{ll} \frac{mn}{p^2} > 1 &  \mbox{for any $S_ U$ distribution} \\ \frac{mn}{p^2} < 1 &  \mbox{for any $S_ B$ distribution} \\ \frac{mn}{p^2} = 1 &  \mbox{for any $S_ L$ (lognormal) distribution} \\ \end{array}  \]](images/procstat_univariate0385.png)
A tolerance interval around one is used to discriminate among the three families with this ratio criterion. You can specify the tolerance with the FITTOLERANCE= option (specified in parentheses after the SB option). The default tolerance is 0.01. Assuming that the criterion satisfies the inequality
 the parameters of the 
 distribution are computed using the explicit formulas derived by Slifker and Shapiro (1980). 
            
If you specify FITMETHOD = MOMENTS (in parentheses after the SB option), the method of moments is used to estimate the parameters. If you specify FITMETHOD = MLE (in parentheses after the SB option), the method of maximum likelihood is used to estimate the parameters. Note that maximum likelihood estimates may not always exist. Refer to Bowman and Shenton (1983) for discussion of methods for fitting Johnson distributions.
The fitted density function is
![\[  p(x) = \left\{  \begin{array}{ll} \frac{ \delta hv}{\sigma \sqrt {2\pi } } \frac{ 1 }{ \sqrt { 1 + \left( (x - \theta ) / \sigma \right)^2 } } \times & \\ \exp \left[ -\frac{1}{2} \left( \gamma + \delta \sinh ^{-1} \left( \frac{x - \theta }{\sigma } \right) \right)^2 \right] &  \mbox{for $ x > \theta $} \\ 0 &  \mbox{for $ x \leq \theta $ } \end{array} \right.  \]](images/procstat_univariate0387.png)
where
 location parameter 
 
                     
 scale parameter 
 
                     
 shape parameter 
 
                     
 shape parameter 
 
                     
 width of histogram interval 
                     
 vertical scaling factor 
                     
and
![\[  v = \left\{  \begin{array}{ll} n &  \mbox{the sample size, for VSCALE=COUNT} \\ 100 &  \mbox{for VSCALE=PERCENT} \\ 1 &  \mbox{for VSCALE=PROPORTION} \end{array} \right.  \]](images/procstat_univariate0313.png)
You can specify the parameters with the THETA=, SIGMA=, DELTA=, and GAMMA= 
-options, which are enclosed in parentheses after the SU option. If you do not specify these parameters, they are estimated.
               
            
By default, the method of percentiles given by Slifker and Shapiro (1980) is used to estimate the parameters. This method is based on four data percentiles, denoted by 
, 
, 
, and 
, which correspond to the four equally spaced percentiles of a standard normal distribution, denoted by 
, 
, 
, and 
, under the transformation 
            
 The default value of 
 is 0.524. The results of the fit are dependent on the choice of 
, and you can specify other values with the FITINTERVAL= option (specified in parentheses after the SU option). If you use
               the method of percentiles, you should select a value of 
 that corresponds to percentiles that are critical to your application. 
            
The following values are computed from the data percentiles:
It was demonstrated by Slifker and Shapiro (1980) that
![\[  \begin{array}{ll} \frac{mn}{p^2} > 1 &  \mbox{for any $S_ U$ distribution} \\ \frac{mn}{p^2} < 1 &  \mbox{for any $S_ B$ distribution} \\ \frac{mn}{p^2} = 1 &  \mbox{for any $S_ L$ (lognormal) distribution} \\ \end{array}  \]](images/procstat_univariate0385.png)
A tolerance interval around one is used to discriminate among the three families with this ratio criterion. You can specify the tolerance with the FITTOLERANCE= option (specified in parentheses after the SU option). The default tolerance is 0.01. Assuming that the criterion satisfies the inequality
 the parameters of the 
 distribution are computed using the explicit formulas derived by Slifker and Shapiro (1980). 
            
If you specify FITMETHOD = MOMENTS (in parentheses after the SU option), the method of moments is used to estimate the parameters. If you specify FITMETHOD = MLE (in parentheses after the SU option), the method of maximum likelihood is used to estimate the parameters. Note that maximum likelihood estimates do not always exist. Refer to Bowman and Shenton (1983) for discussion of methods for fitting Johnson distributions.
The fitted density function is
where
 threshold parameter 
                     
 scale parameter 
 
                     
 shape parameter 
 
                     
 width of histogram interval 
                     
 vertical scaling factor 
                     
and
![\[  v = \left\{  \begin{array}{ll} n &  \mbox{the sample size, for VSCALE=COUNT} \\ 100 &  \mbox{for VSCALE=PERCENT} \\ 1 &  \mbox{for VSCALE=PROPORTION} \end{array} \right.  \]](images/procstat_univariate0313.png)
The threshold parameter 
 must be less than the minimum data value. You can specify 
 with the THRESHOLD= Weibull-option. By default, 
. If you specify THETA=EST, a maximum likelihood estimate is computed for 
. You can specify 
 and 
 with the SCALE= and SHAPE= Weibull-options, respectively. By default, the procedure calculates maximum likelihood estimates for 
 and 
. 
            
The exponential distribution is a special case of the Weibull distribution where 
. 
            
You can use the DATA step function QUANTILE to compute Weibull quantiles and the DATA step function CDF to compute Weibull probabilities.