<label:>MCFPLOT
variable
cost/censor-variable(values) <=group-variables> </ options> ;
<label:>MCFPLOT
(<INTERVAL=>variable1 variable2 <RECURRENCES=> variable3 <CENSOR=> variable4 ) <=group-variables> </ options> ;
<label:>MCFPLOT
(variable1 variable2) <=group-variables> </ options> ;
You can specify any number of MCFPLOT statements after a PROC RELIABILITY statement. Each MCFPLOT statement creates a separate MCF plot and associated analysis. See the section Analysis of Recurrence Data on Repairs, the section Comparison of Two Samples of Repair Data, and the section Analysis of Interval Age Recurrence Data for examples that use the MCFPLOT statement. You can specify an optional label to distinguish between multiple MCFPLOT statements in the output.
To create a plot of the mean cumulative function for cost or number of repairs with exact age data, you specify a variable that represents the times of repairs. You must also specify a cost/censor-variable and the values, in parentheses, of the cost/censor-variable that correspond to end-of-history data values (also referred to as censored data values).
To create a plot of the mean cumulative function for cost or number of repairs with interval age data, you specify variable1 variable2 that represents the age intervals. You must also specify either variable3 that represents the number of recurrences in the intervals and variable4 that represents the number censored in the intervals, or a FREQ statement that represents the number of recurrent events in the intervals and a NENTER statement that represents the number of units observed in the intervals.
You can optionally specify one or two group-variables (also referred to as classification variables). The MCFPLOT statement displays a component plot for each level of the group-variables. The observations in a given level are called a cell.
For exact data, you must also specify a unit-identification variable in conjunction with the MCFPLOT statement to identify the individual unit name for each instance of repair or end of history on the unit. Specify the unit-identification variable in the UNITID statement.
The elements of the MCFPLOT statement are described as follows.
Table 16.21 lists available analysis options.
Table 16.21: Analysis Options
Option |
Option Description |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
CONFIDENCE=number |
Specifies the confidence coefficient for all confidence intervals. Specify a number between 0 and 1. The default value is 0.95. |
||||||||||
INDINC |
Sequests variance estimates of the MCF using the Nelson (2002) estimator under the independent increments assumption. |
||||||||||
LOGINTERVALS |
Requests that confidence intervals be computed based on the asymptotic normality of (MCF). This is appropriate only when the MCF estimate is positive, so does not apply to MCF differences or when negative costs are specified. |
||||||||||
Requests a plot of differences of MCFS of two groups specified by a single group variable. |
|||||||||||
NOVARIANCE |
Suppresses MCF variance computation. |
||||||||||
VARIANCE=variance-specification |
Specifies the method of variance calculation. The following methods are available. |
||||||||||
|
Table 16.22 lists plot layout options that are available when you use traditional graphics.
Table 16.22: Plot Layout Options for Traditional Graphics
Option |
Option Description |
---|---|
CENBIN |
Plots censored data as frequency counts rather than as individual points. |
CENSYMBOL=symbol | (symbol-list) |
Specifies symbols for censored values. symbol is one of the symbol names (plus, star, square, diamond, triangle, hash, paw, point, dot, circle) or a letter (A–Z). If you are creating overlaid plots for groups of data, you can specify different symbols for the groups with a list of symbols or letters, separated by blanks, enclosed in parentheses. If no CENSYMBOL option is specified, the symbol used for censored values is the same as for repairs. |
HOFFSET=value |
Specifies offset for horizontal axis. |
INBORDER |
Requests a border around MCF plots. |
INTERPOLATE=JOIN | STEP | NONE |
Requests that symbols in an MCF plot be connected with a straight line, step function, or not connected. |
INTERTILE=value |
Specifies the distance between tiles. |
MCFLEGEND=legend-statement-name | NONE |
Identifies a legend statement to specify legend for overlaid MCF plots. |
MISSING1 |
Requests that missing values of first GROUP= variable be treated as a level of the variable. |
MISSING2 |
Requests that missing values of second GROUP= variable be treated as a level of the variable. |
NCOLS=n |
Specifies the number of columns plotted on a page. |
NOCENPLOT |
Suppresses plotting of censored data points. |
NOCONF |
Suppresses plotting of confidence intervals. |
NOFRAME |
Suppresses the frame around the plotting area. |
NOINSET |
Suppresses the inset. |
NOLEGEND |
Suppresses the legend for overlaid MCF plots. |
NROWS=n |
Specifies the number of rows plotted on a page. |
ORDER1=DATA | FORMATTED | |
|
FREQ | INTERNAL |
Specifies display order for values of the first GROUP= variable. |
ORDER2=DATA | FORMATTED | |
|
FREQ | INTERNAL |
Specifies display order for values of the second GROUP= variable. |
OVERLAY |
Requests that plots with group variables be overlaid on a single page. |
PLOTSYMBOL=symbol | (symbol-list) |
Specifies symbols that represent events in an MCF plot. |
PLOTCOLOR=color | (color-list) |
Specifies colors of symbols that represent events in an MCF plot. |
TURNVLABELS |
Vertically strings out characters in labels for vertical axis. |
VOFFSET=value |
Specifies length of offset at upper end of vertical axis. |
Table 16.23 lists plot layout options available when you use ODS Graphics.
Table 16.23: Plot Layout Options for ODS Graphics
Option |
Option Description |
---|---|
Requests that a Duane plot be created in addition to an MCF plot. If you specify the FIT=MODEL option, the fitted parametric model is included in the Duane plot. See the section Duane Plots for a description of Duane plots. |
|
Requests that a parametric cumulative mean function fit with a MODEL statement be plotted on the same plot with nonparametric estimates of the MCF. This option is valid only if the response specification in the MCFPLOT statement matches the response specification in the MODEL statement. If this option is specified, the fit parametric intensity function is plotted on a separate graph. |
|
INTERPOLATE=JOIN | STEP | NONE |
Requests that symbols in an MCF plot be connected with a straight line, step function, or not connected. |
MISSING1 |
Requests that missing values of first GROUP= variable be treated as a level of the variable. |
MISSING2 |
Requests that missing values of second GROUP= variable be treated as a level of the variable. |
NCOLS=n |
Specifies the number of columns plotted on a page. |
NOCENPLOT |
Suppresses plotting of censored data points. |
NOCONF |
Suppresses plotting of confidence intervals. |
NOINSET |
Suppresses the inset. |
NROWS=n |
Specifies the number of rows plotted on a page. |
ORDER1=DATA | FORMATTED | |
|
FREQ | INTERNAL |
Specifies the display order for values of the first GROUP= variable. |
ORDER2=DATA | FORMATTED | |
|
FREQ | INTERNAL |
Specifies the display order for values of the second GROUP= variable. |
OVERLAY |
Requests that plots with group variables be overlaid on a single page. |
Table 16.24 lists reference line options that are available when you use traditional graphics.
Table 16.24: Reference Line Options for Traditional Graphics
Option |
Option Description |
||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HREF=value-list |
Specifies reference lines perpendicular to horizontal axis. |
||||||||||||||
HREFLABELS=(’label1’ …’labeln’) |
Specifies labels for HREF= lines. |
||||||||||||||
HREFLABPOS=n |
Specifies the vertical position of labels for HREF= lines. The valid values for n and the corresponding label placements are shown in the following table:
|
||||||||||||||
LHREF=linetype |
Specifies the line style for HREF= lines. |
||||||||||||||
LVREF=linetype |
Specifies the line style for VREF= lines. |
||||||||||||||
VREF=value-list |
Specifies reference lines perpendicular to vertical axis. |
||||||||||||||
VREFLABELS=(’label1’ …’labeln’) |
Specifies labels for VREF= lines. |
||||||||||||||
VREFLABPOS=n |
Specifies the horizontal position of labels for VREF= lines. The valid values for n and the corresponding label placements are shown in the following table:
|
Table 16.25 lists reference line options that are available when you use ODS Graphics.
Table 16.25: Reference Line Options for ODS Graphics
Option |
Option Description |
---|---|
HREF=value-list |
Specifies reference lines perpendicular to the horizontal axis. |
HREFLABELS=(’label1’ …’labeln’) |
specifies labels for HREF= lines. |
VREF=value-list |
Specifies reference lines perpendicular to the vertical axis. |
VREFLABELS=(’label1’ …’labeln’) |
Specifies labels for VREF= lines. |
Table 16.26 lists the options that control the appearance of the text when you use traditional graphics. These options are not available if ODS Graphics is enabled.
Table 16.26: Text Enhancement Options
Option |
Option Description |
---|---|
FONT=font |
Software font for text. |
HEIGHT=value |
Height of text used outside framed areas. |
INFONT=font |
Software font for text inside framed areas. |
INHEIGHT=value |
Height of text inside framed areas. |
Table 16.27 lists options to control the appearance of the axes when you use traditional graphics.
Table 16.27: Axis Options for Traditional Graphics
Option |
Option Description |
---|---|
HAXIS=value1 TO value2<BY value3> |
Specifies tick mark values for the horizontal axis. value1, value2, and value3 must be numeric, and value1 must be less than value2. The lower tick mark is value1. Tick marks are drawn at increments of value3. The last tick mark is the greatest value that does not exceed value2. If value3 is omitted, a value of 1 is used. This method of specification of tick marks is not valid for logarithmic axes. Examples of HAXIS= lists follow: haxis = 0 to 10 haxis = 2 to 10 by 2 haxis = 0 to 200 by 10 |
HLOWER=number |
Specifies the lower limit on the horizontal axis scale. The HLOWER= option specifies number as the lower horizontal axis tick mark. The tick mark interval and the upper axis limit are determined automatically. This option has no effect if the HAXIS option is used. |
HUPPER=number |
Specifies the upper limit on the horizontal axis scale. The HUPPER= option specifies number as the upper horizontal axis tick mark. The tick mark interval and the lower axis limit are determined automatically. This option has no effect if the HAXIS= option is used. |
LGRID=number |
Specifies a line style for all grid lines. number is between 1 and 46 and specifies a linestyle for grids. |
LOGLOG |
Requests log scales on both axes. |
MINORLOGGRID |
Adds a minor grid for log axes. |
NOGRID |
Suppresses grid lines. |
NOHLABEL |
Suppresses label for horizontal axis. |
NOVLABEL |
Suppresses label for vertical axis. |
NOVTICK |
Suppresses tick marks and tick mark labels for vertical axis. |
NOHTICK |
Suppresses tick marks and tick mark labels for horizontal axis. |
NHTICK=number |
Specifies the number of tick intervals for the horizontal axis. This option has no effect if the HAXIS= option is used. |
NVTICK=number |
Specifies the number of tick intervals for the vertical axis. This option has no effect if the VAXIS= option is used. |
VAXIS=value1 TO value2<BY value3> |
Specifies tick mark values for the vertical axis. value1, value2, and value3 must be numeric, and value1 must be less than value2. The lower tick mark is value1. Tick marks are drawn at increments of value3. The last tick mark is the greatest value that does not exceed value2. This method of specification of tick marks is not valid for logarithmic axes. If value3 is omitted, a value of 1 is used. vaxis = 0 to 10 vaxis = 0 to 2 by .1 |
VAXISLABEL=’string’ |
Specifies a label for the vertical axis |
VLOWER=number |
Specifies the lower limit on the vertical axis scale. The VLOWER= option specifies number as the lower vertical axis tick mark. The tick mark interval and the upper axis limit are determined automatically. This option has no effect if the VAXIS= option is used. |
VUPPER=number |
Specifies the upper limit on the vertical axis scale. The VUPPER= option specifies number as the upper vertical axis tick mark. The tick mark interval and the lower axis limit are determined automatically. This option has no effect if the VAXIS= option is used. |
WAXIS=n |
Specifies the line thickness for axes and frame. |
Table 16.28 lists options that control the appearance of the axes when you use ODS Graphics.
Table 16.28: Axis Options for ODS Graphics
Option |
Option Description |
---|---|
HLOWER=number |
Specifies the lower limit on the horizontal axis scale. The HLOWER= option specifies number as the lower horizontal axis tick mark. The tick mark interval and the upper axis limit are determined automatically. This option has no effect if the HAXIS option is used. |
HUPPER=number |
Specifies the upper limit on the horizontal axis scale. The HUPPER= option specifies number as the upper horizontal axis tick mark. The tick mark interval and the lower axis limit are determined automatically. This option has no effect if the HAXIS= option is used. |
LOGLOG |
Requests log scales on both axes. |
MINORLOGGRID |
Adds a minor grid for log axes. |
NOGRID |
Suppresses grid lines. |
VLOWER=number |
Specifies the lower limit on the vertical axis scale. The VLOWER= option specifies number as the lower vertical axis tick mark. The tick mark interval and the upper axis limit are determined automatically. This option has no effect if the VAXIS= option is used. |
VUPPER=number |
Specifies the upper limit on the vertical axis scale. The VUPPER= option specifies number as the upper vertical axis tick mark. The tick mark interval and the lower axis limit are determined automatically. This option has no effect if the VAXIS= option is used. |
Table 16.29 lists options that control colors and patterns used in the graph when you use traditional graphics. These options are not available if ODS Graphics is enabled.
Table 16.29: Color and Pattern Options
Option |
Option Description |
---|---|
CAXIS=color |
Color for axis. |
CCENSOR=color |
Color for filling censor plot area. |
CENCOLOR=color |
Color for censor symbol. |
CFRAME=color |
Color for frame. |
CFRAMESIDE=color |
Color for filling frame for row labels. |
CFRAMETOP=color |
Color for filling frame for column labels. |
CGRID=color |
Color for grid lines. |
CHREF=color |
Color for HREF= lines. |
CTEXT=color |
Color for text. |
CVREF=color |
Color for VREF= lines. |
Table 16.30 lists options that control the use of a graphics catalog to store graphs if you use traditional graphics. These options are not available if ODS Graphics is enabled.
Table 16.30: Graphics Catalog Options
Option |
Option Description |
---|---|
DESCRIPTION=’string’ |
Description for graphics catalog member. |
NAME=’string’ |
Name for plot in graphics catalog. |