Problem Note 70197: Initialization of SAS® 9.4M5 (TS1M5) and later for z/OS fails with a system abend 0C4-10 when the machine is configured for more than 16 processors

DetailsHotfixAboutRate It

During initialization of SAS 9.4M5, SAS scans the Physical Configuration Communication Area (PCCA). Due to a change introduced in SAS Note 60730, initialization of SAS 9.4M5 and later for z/OS abends with the following system abend 0C4-10 and user abend 998 when the machine is configured for more than 16 processors:

SYSTEM COMPLETION CODE=0C4  REASON CODE=00000010
 TIME=15.49.28  SEQ=38233  CPU=0000  ASID=0040
 PSW AT TIME OF ERROR  078D3000   B6638E08  ILC 4  INTC 10
   ACTIVE MODULE           ADDRESS=00000000_36611000  OFFSET=00027E08
   NAME=SASHOST
   DATA AT PSW  36638E02 - FFE758A0  60AC58B0  A0305820
   AR/GR 0: 0000005B/00080000   1: 00000000/000130A0
         2: 00000000/00000000   3: 00000000/8000A000
         4: 00000000/3663EB80   5: 00000000/36638C8C
         6: 00000000/0000B108   7: 00000000/000128C8
         8: 00000000/3666B278   9: 00000000/00080000
         A: 00000000/F0F1F3F5   B: 00000000/8000A000
         C: 00000000/8000A000   D: 00000000/000130C0
         E: 00000000/36615450   F: 00000000/36638C8C

A temporary workaround is to configure the machine for fewer than 16 processors.

Click the Hot Fix tab in this note to access the hot fix for this issue.



Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SAS SystemBase SASz/OS9.4_M59.4 TS1M5
z/OS 64-bit9.4_M59.4 TS1M5