<Exceptions><Exception><SASMessage severity="Error">Lost contact with the server when calling an IOM interface..."" />
Problem Note 66176: The metadata server cluster node can fail and lose quorum when you use the ImportPackage
You might encounter a problem in which metadata server cluster nodes do not successfully sync with each other. When you encounter this problem, you might see messages similar to the following:
WARN [02011161] 15538:sas - <?xml version="1.0" ?><Exceptions><Exception><SASMessage severity="Error">Lost contact with the server when calling an IOM interface.</SASMessage></Exception></Exceptions>
This problem typically occurs under the following conditions:
- You import a package that requires a large number of changes to the metadata servers.
- You use a SAS® 9.4 deployment that contains a metadata server cluster configured with three or more cluster nodes that are in quorum and running normally.
During synchronization, the journal entries become large, which causes communication to time out.
Click the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
SAS System | SAS Metadata Server | z/OS | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft® Windows® for x64 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows 8 Enterprise 32-bit | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows 8 Enterprise x64 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows 8 Pro 32-bit | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows 8 Pro x64 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows 8.1 Enterprise 32-bit | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows 8.1 Enterprise x64 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows 8.1 Pro 32-bit | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows 8.1 Pro x64 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows 10 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows Server 2012 Datacenter | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows Server 2012 R2 Datacenter | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows Server 2012 R2 Std | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows Server 2012 Std | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows Server 2016 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows Server 2019 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Windows 7 Enterprise 32 bit | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Windows 7 Enterprise x64 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Windows 7 Home Premium 32 bit | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Windows 7 Home Premium x64 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Windows 7 Professional 32 bit | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Windows 7 Professional x64 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Windows 7 Ultimate 32 bit | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Windows 7 Ultimate x64 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
64-bit Enabled AIX | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
64-bit Enabled Solaris | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
HP-UX IPF | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Linux for x64 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Solaris for x64 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
The metadata server cluster node might fail, lose quorum, and return the following message: "WARN [02011161] 15538:sas - <?xml version="1.0" ?><Exceptions><Exception><SASMessage severity="Error">Lost contact with the server when calling an IOM interface..."
Type: | Problem Note |
Priority: | high |
Date Modified: | 2020-07-21 07:35:14 |
Date Created: | 2020-06-21 01:37:31 |