Problem Note 59402: SAS/ACCESS® Interface to Greenplum fails to bulk load into tables with "...ERROR: Error initializing Greenplum load..."
When bulk loading into a Greenplum table that contains one or more REAL data types, the following error occurs:
ERROR: Error initializing Greenplum load: [SAS ACCESS to Greenplum][ODBC Greenplum Wire Protocol driver][Greenplum]
ERROR: syntax error at or near ","(Position 58;File scan.l;Line 979;Routine base_yyerror;) :
[SAS ACCESS to Greenplum][ODBC Greenplum Wire Protocol driver][Greenplum]Failed transaction.
The current transaction rolled back.
NOTE: Statements not processed because of errors noted above.
You can work around the problem by not using the bulk-load facility.
Click the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
SAS System | SAS/ACCESS Interface to Greenplum | Microsoft® Windows® for x64 | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows 8 Enterprise 32-bit | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows 8 Enterprise x64 | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows 8 Pro 32-bit | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows 8 Pro x64 | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows 8.1 Enterprise 32-bit | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows 8.1 Enterprise x64 | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows 8.1 Pro 32-bit | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows 8.1 Pro x64 | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows 10 | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows Server 2008 | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows Server 2008 R2 | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows Server 2008 for x64 | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows Server 2012 Datacenter | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows Server 2012 R2 Datacenter | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows Server 2012 R2 Std | 9.4 TS1M2 | 9.4 TS1M3 |
Microsoft Windows Server 2012 Std | 9.4 TS1M2 | 9.4 TS1M3 |
Windows 7 Enterprise 32 bit | 9.4 TS1M2 | 9.4 TS1M3 |
Windows 7 Enterprise x64 | 9.4 TS1M2 | 9.4 TS1M3 |
Windows 7 Home Premium 32 bit | 9.4 TS1M2 | 9.4 TS1M3 |
Windows 7 Home Premium x64 | 9.4 TS1M2 | 9.4 TS1M3 |
Windows 7 Professional 32 bit | 9.4 TS1M2 | 9.4 TS1M3 |
Windows 7 Professional x64 | 9.4 TS1M2 | 9.4 TS1M3 |
Windows 7 Ultimate 32 bit | 9.4 TS1M2 | 9.4 TS1M3 |
Windows 7 Ultimate x64 | 9.4 TS1M2 | 9.4 TS1M3 |
64-bit Enabled AIX | 9.4 TS1M2 | 9.4 TS1M3 |
64-bit Enabled Solaris | 9.4 TS1M2 | 9.4 TS1M3 |
HP-UX IPF | 9.4 TS1M2 | 9.4 TS1M3 |
Linux for x64 | 9.4 TS1M2 | 9.4 TS1M3 |
Solaris for x64 | 9.4 TS1M2 | 9.4 TS1M3 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
'ERROR: Error initializing Greenplum load: [SAS ACCESS to Greenplum][ODBC Greenplum Wire Protocol driver][Greenplum]ERROR: syntax error at or near ","...' occurs when you attempt to use the bulk-load facility to load data into a Greenplum table containing one or more REAL data types.
Type: | Problem Note |
Priority: | high |
Date Modified: | 2016-11-30 10:41:26 |
Date Created: | 2016-11-23 09:03:15 |