Problem Note 45013: Errors occur in SAS® Enterprise Guide® 4.3 when importing a Microsoft Excel named range in a project that was migrated from version 4.1
In SAS Enterprise Guide 4.1, you can import a Microsoft Excel named range or print_area successfully. After that project is migrated to 4.3, errors will occur. If the import data task is modified, a Named Range Missing message box appears. If you click OK in the box, the import data task opens but no sheets or predefined ranges are available to select.
If the process flow is run, the following error occurs:
SAS Enterprise Guide has encountered a problem and needs to close. We are sorry for the inconvenience.
--------------------------------------------------------
System.ArgumentException
Invalid range reference
------------------------------ Technical Information Follows ------------------------------
System.ArgumentException: Invalid range reference
at SAS.Tasks.ImportData.ExcelSpecificInfo.SASCode(Boolean embedData, Boolean
accPCFFAvailable, String serverType, String& log)
at SAS.Tasks.ImportData.ImportDataModel.Run(ISASTaskTextWriter LogWriter)
at SAS.Shared.AddIns.Management.AddInProxy.Run(ISASTaskTextWriter LogWriter)
at
SAS.EG.ProjectElements.EGTask.CustomJobExecutionThroughSasTaskExecution(Job job)
at SAS.EG.ProjectElements.EGTask.OnJobExecuting(Job job)
at SAS.EG.ProjectElements.SubmitableElement.HandleJobExecuting(Object sender,
EventArgs e)
at SAS.EG.JobManagement.JobSequenceManager.OnExecuting(EventArgs e)
at SAS.EG.JobManagement.JobSequenceManager.HandleJobExecuting(Object sender,
EventArgs e)
at SAS.EG.JobManagement.Job.OnExecuting(EventArgs e)
at SAS.EG.JobManagement.Job.Execute()
at SAS.EG.JobManagement.Job.HandleJobUnblocked(Object state, Boolean
timedOut)
at
System.Threading._ThreadPoolWaitOrTimerCallback.WaitOrTimerCallback_Context(Obje
ct state, Boolean timedOut)
at
System.Threading._ThreadPoolWaitOrTimerCallback.WaitOrTimerCallback_Context_f(Ob
ject state)
at System.Threading.ExecutionContext.Run(ExecutionContext executionContext,
ContextCallback callback, Object state)
at
System.Threading._ThreadPoolWaitOrTimerCallback.PerformWaitOrTimerCallback(Objec
t state, Boolean timedOut)
------------------------------ End of Technical Information ------------------------------
However, the same Excel named range can be imported successfully in a new SAS Enterprise Guide 4.3 project.
Click the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
SAS System | SAS Enterprise Guide | Microsoft® Windows® for x64 | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Microsoft Windows Server 2003 Datacenter Edition | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Microsoft Windows Server 2003 Enterprise Edition | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Microsoft Windows Server 2003 Standard Edition | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Microsoft Windows Server 2003 for x64 | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Microsoft Windows Server 2008 | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Microsoft Windows Server 2008 for x64 | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Microsoft Windows XP Professional | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Windows 7 Enterprise 32 bit | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Windows 7 Enterprise x64 | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Windows 7 Home Premium 32 bit | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Windows 7 Home Premium x64 | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Windows 7 Professional 32 bit | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Windows 7 Professional x64 | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Windows 7 Ultimate 32 bit | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Windows 7 Ultimate x64 | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Windows Vista | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
Windows Vista for x64 | 4.3 | 5.1 | 9.2 TS2M3 | 9.3 TS1M0 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
Type: | Problem Note |
Priority: | high |
Date Modified: | 2012-01-22 22:41:13 |
Date Created: | 2011-12-02 15:03:05 |