See SHWIR1 in the SAS/QC Sample LibraryYou can save the control limits for individual measurements and moving range charts in a SAS data set; this enables you to apply the control limits to future data (see Reading Preestablished Control Limits) or modify the limits with a DATA step program.
The following statements read the diameter measurements from the data set Jets
(see Creating Individual Measurements and Moving Range Charts) and save the control limits displayed in Figure 17.26 in a data set named Jetlim
:
proc shewhart data=Jets; irchart Diam*Engine / outlimits = Jetlim nochart; run;
The OUTLIMITS= option names the data set containing the control limits, and the NOCHART option suppresses the display of the
charts. The data set Jetlim
is listed in Figure 17.29.
Figure 17.29: The Data Set Jetlim
Containing Control Limit Information
Control Limits for Diameters |
_VAR_ | _SUBGRP_ | _TYPE_ | _LIMITN_ | _ALPHA_ | _SIGMAS_ | _LCLI_ | _MEAN_ | _UCLI_ | _LCLR_ | _R_ | _UCLR_ | _STDDEV_ |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Diam | Engine | ESTIMATE | 2 | .002699796 | 3 | 66.2290 | 80.39 | 94.5510 | 0 | 5.32632 | 17.3986 | 4.72032 |
The data set Jetlim
contains one observation with the limits for process Diam
. The variables _LCLI_
and _UCLI_
contain the control limits for the individual measurements, and the variable _MEAN_
contains the central line. The variables _LCLR_
and _UCLR_
contain the control limits for the moving ranges, and the variable _R_
contains the central line. The value of _MEAN_
is an estimate of the process mean, and the value of _STDDEV_
is an estimate of the process standard deviation . The value of _LIMITN_
is the number of consecutive measurements used to compute the moving ranges, and the value of _SIGMAS_
is the multiple of associated with the control limits. The variables _VAR_
and _SUBGRP_
are bookkeeping variables that save the process and subgroup-variable. The variable _TYPE_
is a bookkeeping variable that indicates whether the values of _MEAN_
and _STDDEV_
are estimates or standard values. For more information, see OUTLIMITS= Data Set.
You can create an output data set containing both control limits and summary statistics with the OUTTABLE= option, as illustrated by the following statements:
proc shewhart data=Jets; irchart Diam*Engine / outtable=Jtable nochart; run;
The data set Jtable
is listed in Figure 17.30.
Figure 17.30: The Data Set Jtable
Summary Statistics and Control Limit Information |
_VAR_ | Engine | _SIGMAS_ | _LIMITN_ | _LCLI_ | _SUBI_ | _MEAN_ | _UCLI_ | _STDDEV_ | _EXLIM_ | _LCLR_ | _SUBR_ | _R_ | _UCLR_ | _EXLIMR_ |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Diam | 1 | 3 | 2 | 66.2290 | 78.4 | 80.39 | 94.5510 | 4.72032 | 0 | . | 5.32632 | 17.3986 | ||
Diam | 2 | 3 | 2 | 66.2290 | 80.1 | 80.39 | 94.5510 | 4.72032 | 0 | 1.7 | 5.32632 | 17.3986 | ||
Diam | 3 | 3 | 2 | 66.2290 | 84.4 | 80.39 | 94.5510 | 4.72032 | 0 | 4.3 | 5.32632 | 17.3986 | ||
Diam | 4 | 3 | 2 | 66.2290 | 79.1 | 80.39 | 94.5510 | 4.72032 | 0 | 5.3 | 5.32632 | 17.3986 | ||
Diam | 5 | 3 | 2 | 66.2290 | 80.4 | 80.39 | 94.5510 | 4.72032 | 0 | 1.3 | 5.32632 | 17.3986 | ||
Diam | 6 | 3 | 2 | 66.2290 | 83.5 | 80.39 | 94.5510 | 4.72032 | 0 | 3.1 | 5.32632 | 17.3986 | ||
Diam | 7 | 3 | 2 | 66.2290 | 73.8 | 80.39 | 94.5510 | 4.72032 | 0 | 9.7 | 5.32632 | 17.3986 | ||
Diam | 8 | 3 | 2 | 66.2290 | 83.5 | 80.39 | 94.5510 | 4.72032 | 0 | 9.7 | 5.32632 | 17.3986 | ||
Diam | 9 | 3 | 2 | 66.2290 | 75.0 | 80.39 | 94.5510 | 4.72032 | 0 | 8.5 | 5.32632 | 17.3986 | ||
Diam | 10 | 3 | 2 | 66.2290 | 76.8 | 80.39 | 94.5510 | 4.72032 | 0 | 1.8 | 5.32632 | 17.3986 | ||
Diam | 11 | 3 | 2 | 66.2290 | 70.5 | 80.39 | 94.5510 | 4.72032 | 0 | 6.3 | 5.32632 | 17.3986 | ||
Diam | 12 | 3 | 2 | 66.2290 | 80.3 | 80.39 | 94.5510 | 4.72032 | 0 | 9.8 | 5.32632 | 17.3986 | ||
Diam | 13 | 3 | 2 | 66.2290 | 82.4 | 80.39 | 94.5510 | 4.72032 | 0 | 2.1 | 5.32632 | 17.3986 | ||
Diam | 14 | 3 | 2 | 66.2290 | 79.4 | 80.39 | 94.5510 | 4.72032 | 0 | 3.0 | 5.32632 | 17.3986 | ||
Diam | 15 | 3 | 2 | 66.2290 | 86.4 | 80.39 | 94.5510 | 4.72032 | 0 | 7.0 | 5.32632 | 17.3986 | ||
Diam | 16 | 3 | 2 | 66.2290 | 90.5 | 80.39 | 94.5510 | 4.72032 | 0 | 4.1 | 5.32632 | 17.3986 | ||
Diam | 17 | 3 | 2 | 66.2290 | 77.7 | 80.39 | 94.5510 | 4.72032 | 0 | 12.8 | 5.32632 | 17.3986 | ||
Diam | 18 | 3 | 2 | 66.2290 | 82.5 | 80.39 | 94.5510 | 4.72032 | 0 | 4.8 | 5.32632 | 17.3986 | ||
Diam | 19 | 3 | 2 | 66.2290 | 79.9 | 80.39 | 94.5510 | 4.72032 | 0 | 2.6 | 5.32632 | 17.3986 | ||
Diam | 20 | 3 | 2 | 66.2290 | 83.2 | 80.39 | 94.5510 | 4.72032 | 0 | 3.3 | 5.32632 | 17.3986 |
This data set contains one observation for each subgroup. The variables _SUBI_
and _SUBR_
contain the individual measurements and moving ranges. The variables _LCLI_
and _UCLI_
contain the lower and upper control limits for the individual measurements chart, and the variables _LCLR_
and _UCLR_
contain the lower and upper control limits for the moving range chart. The variable _MEAN_
contains the central line of the individual measurements chart, and the variable _R_
contains the central line of the moving range chart. The variables _VAR_
and Engine
contain the process name and values of the subgroup-variable, respectively. For more information, see OUTTABLE= Data Set.
An OUTTABLE= data set can be read later as a TABLE= data set. For example, the following statements read Jtable
and display charts (not shown here) identical to those in Figure 17.26:
title 'Individual Measurements and Moving Range Control Charts'; title2 'Jet Engine Diameters (cm)'; proc shewhart table=Jtable; irchart Diam*Engine; run;
Because the SHEWHART procedure simply displays the information in a TABLE= data set, you can use TABLE= data sets to create specialized control charts (see Specialized Control Charts: SHEWHART Procedure).
For more information, see TABLE= Data Set.