For SYSTEM 2000 Version: 1.0
Problem Status: ZD -- V1 FFD1
Description of Problem:
AN S0C6 ABEND MAY OCCUR IN ERROR RECOVERY ROUTINE
Note: Please send email to s2k@sas.com telling us which problem fixes you have downloaded so we can keep track of the fixes at your site in case questions or problems arise.
Top of Zap Deck:
* IBM V1.0 BUG 4976 MVS * * UPON ENTERING STAE LOGIC AFTER AN ABEND IN LOADTSK * A BRANCH IS MADE TO A STORAGE LOCATION REFERENCED * BY THE SECOND BASE REGISTER BUT THE SECOND BASE * REGISTER HAS NOT BEEN LOADED YET. * * THE FIX IS TO BRANCH TO THIS LOCATION FROM THE FIRST * BASE REGISTER. * NAME LOADTSK LOADTSK VER 112C 58FF,000C,58CF,0000 VER 1432 5830,D134,D207,3000,D1DA,5830 REP 112C 182F,47F0,2306,0700 REP 1432 58FF,000C,58CF,0000,47F0,2010 CHECKSUM 67258EE7
End of Zap Deck