Problem Fix Number: 4971

For SYSTEM 2000 Version: 1.0

Problem Status: ZD -- V1 FFD1

Description of Problem:

WHEN A DYNAMICALLY ALLOCATED SAVE FILE GDG NAME IS BUILT USING THE S2K PREFIX VALUE, THE SAME GENERATION NUMBER IS USED FOR EACH SAVE COMMAND ISSUED D


Download Fix:

Note:   Please send email to s2k@sas.com telling us which problem fixes you have downloaded so we can keep track of the fixes at your site in case questions or problems arise.


Top of Zap Deck:

 *  IBM V1.0    BUG 4971  MVS                                                    
 *                                                                               
 * WITHOUT THIS FIX, WHEN A DYNAMICALLY ALLOCATED SAVE FILE NAME IS              
 * BUILT USING THE S2K PREFIX VALUE, THE SAME GENERATION NUMBER IS               
 * USED FOR EACH SAVE COMMAND ISSUED DURING THE SAME S2K SESSION.                
 *                                                                               
 * THIS FIX CAUSES THE GENERATION NUMBER TO BE INCREMENTED EACH TIME             
 * THE SAVE COMMAND IS ISSUED DURING AN S2K SESSION.                             
 *                                                                               
 NAME SYS2K COPRIM                                                               
 VER 05BA 4420,C642,47F0,C66A                                                    
 REP 05BA 58F0,A068,47F0,F3C2                                                    
 NAME SYS2K S2KPATCH                                                             
 VER 03C2 0000,0000,0000,0000,0000,0000                                          
 REP 03C2 4420,C642,5810,D05C,47F0,C5FA                                          
 CHECKSUM 1B2C864E                                                               

End of Zap Deck