Resources



Problem Fix Number: 4895

For SYSTEM 2000 Version: 12.1

Problem Status: ZD -- R12.1 FFD3

Description of Problem:

PLXPBLD CAUSES AMODE AND RMODE TO BE 24 UNLESS YOU OVERRIDE LINKAGE EDITOR EXECUTION PARAMETERS.


Download Fix:

Note:   Please send email to s2k@sas.com telling us which problem fixes you have downloaded so we can keep track of the fixes at your site in case questions or problems arise.


Top of Zap Deck:

 *  IBM R12.1   BUG 4895  MVS                                                    
 *  IBM R12.1   BUG 4895  MVS                                                    
 ./ ADD NAME=B4895                                                               
 ./ NUMBER NEW1=1000,INCR=1000                                                   
 PLXPBLD LOAD MODULE IS AMODE=31 AND RMODE=ANY, BUT THE                          
 CSECT PLXPBLD WITHIN THE LOAD MODULE IS AMODE=24 AND RMODE=24.                  
 UNLESS YOU SPECIFY AMODE=31 AND RMODE=ANY ON THE LINKAGE EDITOR                 
 PARAMETER, PLXPBLD WILL CAUSE YOUR COBOL II PROGRAM TO BE                       
 AMODE=24 AND RMODE=24.                                                          
 AFTER APPLYING THIS FIX, PLXPBLD CSECT WILL MATCH THE LOAD MODULE.              
 USE JCLCPLEX TO RECOMPILE AND LINK PLXPBLD.                                     
 ./ CHANGE NAME=PLXPBLD                                                          
 PLXPBLD  AMODE 31                                                       00004010
 PLXPBLD  RMODE ANY                                                      00004020
 * *03* 11NOV97 MUK B4895 MAKE PLXPBLD AMODE=31, RMODE=ANY          *03* 00017900

End of Zap Deck