Resources



Problem Fix Number: 4831

For SYSTEM 2000 Version: 12.0

Problem Status: ZC (Zap Coded) -- Fix has received limited testing

Description of Problem:

A PLEX SAVE OR KEEP COMMAND USING THE VOLUME AND SEQUENCE NUMBER SYNTAX HAS THE SEQUENCE NUMBER WRITTEN INTO POSITION 3 AND 4 OF THE VOLUME NAME.


Download Fix:

Note:   Please send email to s2k@sas.com telling us which problem fixes you have downloaded so we can keep track of the fixes at your site in case questions or problems arise.


Top of Zap Deck:

 *  IBM V12.0   BUG 4831  MVS                                                    
 *                                                                               
 * PLEX SAVE OR KEEP COMMAND USING THE VOLUME AND SEQUENCE NUMBER                
 * SYNTAX HAS THE SEQUENCE NUMBER OVERWRITE POSITIONS 3 AND 4 OF                 
 * THE VOLUME NAME                                                               
 *                                                                               
 * YOU MUST RUN PRELINK AFTER APPLYING THIS ZAP                                  
 *                                                                               
 NAME S2K50 MOVREL                                                               
 VER 00A0 A82A                                                                   
 VER 0112 A88E                                                                   
 REP 00A0 A808                                                                   
 REP 0112 A888                                                                   
 CHECKSUM 0366A148                                                               