Resources



Problem Fix Number: 4544

For SYSTEM 2000 Version: 12.0

Problem Status: ZD -- ZAP DISTRIBUTED

Description of Problem:

UNDEFINED OPCODE FOR AUTHFUNC WHEN ASSEMBLING MRISVC FOR THE SVC VERSION OF MU.


Download Fix:

Note:   Please send email to s2k@sas.com telling us which problem fixes you have downloaded so we can keep track of the fixes at your site in case questions or problems arise.


Top of Zap Deck:

 *  IBM R12.0   BUG 4544  OS                                                     
 *                                                                               
 *  ASSEMBLE OF MRISVC RESULTS IN UNDEFINED OPCODE FOR AUTHFUNC.                 
 *  ADD THE AUTHFUNC MACRO TO THE R12.0 TEST LIBRARY.  MRISVC NEEDS              
 *  TO BE REASSEMBLED AND LINKED AFTER A SUCCESSFUL IEBUPDTE.                    
 *  THIS ZAP IS FOR THE MU SVC VERSION ONLY!                                     
 *                                                                               
 ./ ADD NAME=AUTHFUNC,SEQFLD=736,LEVEL=00,SOURCE=0,LIST=ALL                      
          MACRO                                                                  
          AUTHFUNC                                                               
          SPACE                                                                  
 FUNC17   DS    0H                                                               
          B     RTN0        SET RETURN CODE ZERO                                 
          MEND                                                                   

End of Zap Deck