For SYSTEM 2000 Version: 11.63
Problem Status: ZC (Zap Coded) -- Fix has received limited testing
Description of Problem:
S30E IN CMS WHEN EXECUTING A 31-BIT PLEX PROGRAM IN VM/XA OR VM/ESA.
Note: Please send email to s2k@sas.com telling us which problem fixes you have downloaded so we can keep track of the fixes at your site in case questions or problems arise.
Top of Zap Deck:
* IBM R11.63 BUG 4680 CMS * * S30E IN CMS WHEN EXECUTING A 31-BIT PLEX PROGRAM IN VM/XA OR VM/ESA. * EXECUTE THE FOLLOWING 4 STEPS TO RELINK S2KPLR AS AMODE=ANY, RMODE=24. * THIS ASSUMES THE S2KLDLIB LOADLIB IS ON YOUR 'D' DISK. * * 1. CREATE AN S2KPLR TEXT FILE CONTAINING THE FOLLOWING LINK-EDIT COMMANDS. * (NOTE - THE COMMANDS START IN COLUMN 2) * INCLUDE LOAD1 (S2KPLR) * ENTRY S2KPLR * NAME S2KPLR(R) * * 2. CREATE A LNKPLR EXEC TO RELINK S2KPLR AS AMODE=ANY, RMODE=24. * /* EXEC TO RELINK S2KPLR AS AMODE=ANY, RMODE=24 */ * "FI LOAD1 DISK S2KLDLIB LOADLIB D(RECFM U BLKSIZE 32760" * "FI SYSLMOD DISK S2KPLR LOADLIB A (RECFM U BLKSIZE 32760" * LKED S2KPLR "(LIBE S2KPLR RENT XREF LET NCAL AMODE ANY RMODE 24" * * 3. EXECUTE THE LNKPLR EXEC. * LNKPLR * * 4. COPY THE S2KPLR LOADLIB INTO THE S2KLDLIB LOADLIB. * LOADLIB COPY S2KPLR LOADLIB A S2KLDLIB LOADLIB D(REPLACE
End of Zap Deck