Resources



Problem Fix Number: 4616

For SYSTEM 2000 Version: 11.63

Problem Status: ZC (Zap Coded) -- Fix has received limited testing

Description of Problem:

S0C1 IN XBUFSIP DURING MU INITIALIZATION WHEN SPECIFYING 8 BUFFER POOLS (POOL0 - POOL7) AND XBUF=YES.


Download Fix:

Note:   Please send email to s2k@sas.com telling us which problem fixes you have downloaded so we can keep track of the fixes at your site in case questions or problems arise.


Top of Zap Deck:

 *  IBM V11.63  BUG 4616  OS                                                     
 *                                                                               
 *  S0C1 IN XBUFSIP DURING MU INITIALIZATION WHEN XBUF=YES AND 8 BUFFER          
 *  POOLS ARE SPECIFIED (POOL0 - POOL7).                                         
 *                                                                               
 NAME S2KXBUF XBUFSIP                                                            
 VER 02D8 4170,0007                                                              
 REP 02D8 4170,0008                                                              
 CHECKSUM 444F4450                                                               

End of Zap Deck