Problem Note 70487: Code run with the SAS® In-Database Code Accelerator for Hadoop on a SAS® Workspace Server might return an error when writing to a local XML file
When you run PROC DS2 code with the SAS In-Database Code Accelerator for Hadoop on a SAS Workspace Server session, errors similar to the following might occur when creating an XML file to a local file system temp:
NOTE: Running THREAD program in-database
NOTE: ERROR: Physical file does not exist, C:\Users\dbiadmin\AppData\Local\Temp\2\SAS Temporary Files\_TD108364_DMCON9408X6F_\#LN01289.
ERROR: Failed to get the format XML.
ERROR: Error returned from tkedsPubINDBDS2.
NOTE: Execution succeeded. No rows affected.
The same code runs without errors in a SAS® Foundation session.
Click the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
SAS System | SAS In-Database Code Accelerator for Hadoop | Microsoft® Windows® for x64 | 9.4 TS1M8 | |
Microsoft Windows 8 Enterprise 32-bit | 9.4 TS1M8 | |
Microsoft Windows 8 Enterprise x64 | 9.4 TS1M8 | |
Microsoft Windows 8 Pro 32-bit | 9.4 TS1M8 | |
Microsoft Windows 8 Pro x64 | 9.4 TS1M8 | |
Microsoft Windows 8.1 Enterprise 32-bit | 9.4 TS1M8 | |
Microsoft Windows 8.1 Enterprise x64 | 9.4 TS1M8 | |
Microsoft Windows 8.1 Pro 32-bit | 9.4 TS1M8 | |
Microsoft Windows 8.1 Pro x64 | 9.4 TS1M8 | |
Microsoft Windows 10 | 9.4 TS1M8 | |
Microsoft Windows 11 | 9.4 TS1M8 | |
Microsoft Windows Server 2008 | 9.4 TS1M8 | |
Microsoft Windows Server 2008 R2 | 9.4 TS1M8 | |
Microsoft Windows Server 2008 for x64 | 9.4 TS1M8 | |
Microsoft Windows Server 2012 Datacenter | 9.4 TS1M8 | |
Microsoft Windows Server 2012 R2 Datacenter | 9.4 TS1M8 | |
Microsoft Windows Server 2012 R2 Std | 9.4 TS1M8 | |
Microsoft Windows Server 2012 Std | 9.4 TS1M8 | |
Microsoft Windows Server 2016 | 9.4 TS1M8 | |
Microsoft Windows Server 2019 | 9.4 TS1M8 | |
Microsoft Windows Server 2022 | 9.4 TS1M8 | |
Windows 7 Enterprise 32 bit | 9.4 TS1M8 | |
Windows 7 Enterprise x64 | 9.4 TS1M8 | |
Windows 7 Home Premium 32 bit | 9.4 TS1M8 | |
Windows 7 Home Premium x64 | 9.4 TS1M8 | |
Windows 7 Professional 32 bit | 9.4 TS1M8 | |
Windows 7 Professional x64 | 9.4 TS1M8 | |
Windows 7 Ultimate 32 bit | 9.4 TS1M8 | |
Windows 7 Ultimate x64 | 9.4 TS1M8 | |
64-bit Enabled AIX | 9.4 TS1M8 | |
64-bit Enabled Solaris | 9.4 TS1M8 | |
HP-UX IPF | 9.4 TS1M8 | |
Linux for x64 | 9.4 TS1M8 | |
Solaris for x64 | 9.4 TS1M8 | |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
In this scenario, a message similar to the following occurs: "ERROR: Physical file does not exist... Failed to get the format XML. ERROR: Error returned from tkedsPubINDBDS2..."
Type: | Problem Note |
Priority: | high |
Date Modified: | 2023-11-03 16:10:55 |
Date Created: | 2023-11-03 13:33:55 |