Problem Note 70458: SAS® Micro Analytic Service might fail to start if it contains many modules
When you start SAS Micro Analytic Service, it might fail and the last line of sas-microanalyticservice log file might contain the following status message:
System Aborting Status=803fc21e
This issue might occur if the SAS Micro Analytic Service contains many large modules, and it takes more than two hours to load all the modules.
To work around this issue, add the following configuration for Micro Analytic Score service:
key: java_option_check_critical_timeout
value: -Dspring.cloud.consul.discovery.healthCheckCriticalTimeout=3h
Click the Hot Fix tab in this note for a link to instructions about accessing and applying the software update.
Operating System and Release Information
SAS System | SAS Micro Analytic Service | Microsoft® Windows® for x64 | 5.5 | | Viya | |
Linux for x64 | 5.5 | | Viya | |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
When it fails to start, this line occurs in the sas-microanalyticservice log file: "System Aborting Status=803fc21e."
Type: | Problem Note |
Priority: | high |
Date Modified: | 2023-10-24 09:09:00 |
Date Created: | 2023-10-20 09:16:03 |