Problem Note 69972: Using SAS/ACCESS® Interface to ODBC together with a SAP HANA ODBC driver might cause an insufficient memory error
If you use SAS/ACCESS Interface to ODBC with a SAP HANA ODBC driver, the following error might occur:
ERROR: The SAS System stopped processing this step because of insufficient memory.
This issue occurs when you use the SAP HANA ODBC driver versions 02.15.0019 (2022-12-28) or later.
To circumvent this issue, use an earlier version of the SAP HANA ODBC driver or use SAS/ACCESS® Interface to SAP HANA.
Click the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
SAS System | SAS/ACCESS Interface to ODBC | Microsoft® Windows® for x64 | 9.4 TS1M8 | |
Microsoft Windows 8 Enterprise 32-bit | 9.4 TS1M8 | |
Microsoft Windows 8 Enterprise x64 | 9.4 TS1M8 | |
Microsoft Windows 8 Pro 32-bit | 9.4 TS1M8 | |
Microsoft Windows 8 Pro x64 | 9.4 TS1M8 | |
Microsoft Windows 8.1 Enterprise 32-bit | 9.4 TS1M8 | |
Microsoft Windows 8.1 Enterprise x64 | 9.4 TS1M8 | |
Microsoft Windows 8.1 Pro 32-bit | 9.4 TS1M8 | |
Microsoft Windows 8.1 Pro x64 | 9.4 TS1M8 | |
Microsoft Windows 10 | 9.4 TS1M8 | |
Microsoft Windows 11 | 9.4 TS1M8 | |
Microsoft Windows Server 2008 | 9.4 TS1M8 | |
Microsoft Windows Server 2008 R2 | 9.4 TS1M8 | |
Microsoft Windows Server 2008 for x64 | 9.4 TS1M8 | |
Microsoft Windows Server 2012 Datacenter | 9.4 TS1M8 | |
Microsoft Windows Server 2012 R2 Datacenter | 9.4 TS1M8 | |
Microsoft Windows Server 2012 R2 Std | 9.4 TS1M8 | |
Microsoft Windows Server 2012 Std | 9.4 TS1M8 | |
Microsoft Windows Server 2016 | 9.4 TS1M8 | |
Microsoft Windows Server 2019 | 9.4 TS1M8 | |
Microsoft Windows Server 2022 | 9.4 TS1M8 | |
Windows 7 Enterprise 32 bit | 9.4 TS1M8 | |
Windows 7 Enterprise x64 | 9.4 TS1M8 | |
Windows 7 Home Premium 32 bit | 9.4 TS1M8 | |
Windows 7 Home Premium x64 | 9.4 TS1M8 | |
Windows 7 Professional 32 bit | 9.4 TS1M8 | |
Windows 7 Professional x64 | 9.4 TS1M8 | |
Windows 7 Ultimate 32 bit | 9.4 TS1M8 | |
Windows 7 Ultimate x64 | 9.4 TS1M8 | |
64-bit Enabled AIX | 9.4 TS1M8 | |
64-bit Enabled Solaris | 9.4 TS1M8 | |
HP-UX IPF | 9.4 TS1M8 | |
Linux for x64 | 9.4 TS1M8 | |
Solaris for x64 | 9.4 TS1M8 | |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
Using SAS/ACCESS Interface to ODBC together with a SAP HANA ODBC driver might result in ERROR: The SAS System stopped processing this step because of insufficient memory.
This issue can occur when you use the SAP HANA ODBC driver versions 02.15.0019 (2022-12-28) or later.
Type: | Problem Note |
Priority: | medium |
Date Modified: | 2023-04-12 15:15:44 |
Date Created: | 2023-03-27 04:25:35 |