SUPPORT / SAMPLES & SAS NOTES
 

Support

Problem Note 68329: Input for a treatment set disappears after you set it in SAS® Real-Time Decision Manager

DetailsHotfixAboutRate It

In SAS Real-Time Decision Manager, input for a treatment set disappears after you set it and click OK. This problem is known to happen when the input value is of type Grid and an upstream node to the cell contains a branch node.

In the example below,the Value cell is empty. You can enter a variable for Value. However, the variable is removed when you click OK.

Value cell

To work around this problem, remove the branch node that is upstream to the cell and then add it again.

Click the Hot Fix tab in this note to access the hot fix for this issue.



Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SAS SystemSAS Real-Time Decision ManagerMicrosoft® Windows® for x646.6
64-bit Enabled AIX6.6
64-bit Enabled Solaris6.6
Linux for x646.6
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.