Problem Note 66924: The SAS® Visual Analytics Viewer might stop responding when loading a report
The SAS Visual Analytics Viewer might stop responding while loading some reports. This problem can be observed in scenarios in which interactions between multiple data sources are in some type of loop.
This issue is similar to the issue described in SAS Note 66179, except that it occurs with SAS Visual Analytics Viewer instead of SAS Visual Analytics Designer. The problem occurs when a data source is filtered by a calculated variable that is based on a parameter. The parameter itself is based on a selection from a report-level prompt. This behavior causes a loop that triggers this issue.
The only workaround is to change the report design. For example, you can use a section-level prompt instead of a report-level prompt.
Click the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
SAS System | SAS Visual Analytics | Linux for x64 | 7.5 | 7.52 | 9.4 TS1M6 | 9.4 TS1M8 |
Microsoft® Windows® for x64 | 7.5 | 7.52 | 9.4 TS1M6 | 9.4 TS1M8 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.