Problem Note 66118: A logon failure occurs and the error "Service...not found in service registry" is generated when you try to log on to SAS® Web Application Server
Logging on to SAS Web Application Server fails when Integrated Windows Authentication (IWA) and fallback authentication are configured and you try to access an affected application via fallback.This problem happens when you try to access the application from a browser that is not configured for IWA or when you attempt it from outside the IWA domain.
If you configure SAS Web Application Server for Integrated Windows Authentication (IWA) and for fallback authentication and try to log on to a SAS web application from a browser that is not configured for IWA or is outside the IWA domain, the logon attempt fails and the following error is displayed in the container log (catalina.out or wrapper.log) file:
WARN org.jasig.cas.CentralAuthenticationServiceImpl - ServiceManagement: Unauthorized Service Access. Service [https://host-name.example.com:8343/PlatformWebServices/ws/users?rolename s=cluster_admin] not found in Service Registry.
There is no workaround for this problem.
A hot fix is planned for this issue.
Operating System and Release Information
SAS System | SAS Web Application Server | Solaris for x64 | 9.45 | 9.45 | 9.4 TS1M6 | 9.4 TS1M6 |
Linux for x64 | 9.45 | 9.45 | 9.4 TS1M6 | 9.4 TS1M6 |
HP-UX IPF | 9.45 | 9.45 | 9.4 TS1M6 | 9.4 TS1M6 |
64-bit Enabled Solaris | 9.45 | 9.45 | 9.4 TS1M6 | 9.4 TS1M6 |
64-bit Enabled AIX | 9.45 | 9.45 | 9.4 TS1M6 | 9.4 TS1M6 |
Microsoft® Windows® for x64 | 9.45 | 9.45 | 9.4 TS1M6 | 9.4 TS1M6 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
Type: | Problem Note |
Priority: | medium |
Date Modified: | 2020-06-11 15:54:55 |
Date Created: | 2020-06-11 10:55:16 |