SUPPORT / SAMPLES & SAS NOTES
 

Support

Problem Note 65715: Unexpected results can occur because the SYSCC automatic macro variable does not reset to zero within SAS® Data Integration Studio job code

DetailsHotfixAboutRate It

The SYSCC automatic macro variable retains a nonzero return code value from a prior execution of a SAS Data Integration Studio job. Unexpected results can occur in a subsequent execution of the job, even if the cause of the nonzero return code is addressed, because the nonzero return code is not reset.  

The workaround for this issue is to insert the following line of code under Job Properties within the Precode section on the Precode and Postcode tab:

%let SYSCC=0;

Click the Hot Fix tab in this note to access the hot fix for this issue.



Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SAS SystemSAS Data Integration StudioWindows 7 Professional x644.74.9059.4 TS1M09.4 TS1M7
Windows 7 Enterprise x644.74.9059.4 TS1M09.4 TS1M7
Microsoft Windows Server 2012 Std4.74.9059.4 TS1M09.4 TS1M7
Microsoft Windows Server 2012 R2 Std4.74.9059.4 TS1M09.4 TS1M7
Microsoft Windows Server 2012 R2 Datacenter4.74.9059.4 TS1M09.4 TS1M7
Microsoft Windows Server 2012 Datacenter4.74.9059.4 TS1M09.4 TS1M7
Microsoft Windows Server 2008 for x644.79.4 TS1M0
Microsoft Windows Server 2008 R24.79.4 TS1M0
Microsoft Windows 104.74.9059.4 TS1M09.4 TS1M7
Microsoft Windows 8.1 Pro x644.74.9059.4 TS1M09.4 TS1M7
Microsoft Windows 8.1 Pro 32-bit4.74.9059.4 TS1M09.4 TS1M7
Microsoft Windows 8.1 Enterprise x644.74.9059.4 TS1M09.4 TS1M7
Microsoft Windows 8.1 Enterprise 32-bit4.74.9059.4 TS1M09.4 TS1M7
Microsoft Windows 8 Pro x644.74.9059.4 TS1M09.4 TS1M7
Microsoft Windows 8 Enterprise x644.74.9059.4 TS1M09.4 TS1M7
Microsoft® Windows® for x644.74.9059.4 TS1M09.4 TS1M7
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.