Problem Note 64562: Cognos does not connect to SAS® Federation Server 4.2 via the provided ODBC driver and you see messages regarding error HY092

DetailsHotfixAboutRate It

A Cognos connection to SAS Federation Server 4.2 fails, and you see the following error messages in the log file created by Cognos:

ENTER: SQLGetInfo(ConnectionHandle = 0xc08110, info = SQL_OUTER_JOINS, Value=, BufferLength = 1028, StringLenPtr = 0)
EXIT: SQL_ERROR = SQLGetInfo(ConnectionHandle = 0xc08110, info = SQL_OUTER_JOINS, Value=, BufferLength = 1028, StringLenPtr = 0)
ENTER: SQLGetDiagRec(HandleType = SQL_HANDLE_DBC, Handle = 0xc08110, RecNumber = 1, SQLState = , NativeErrorPtr = 0, MessageText = , BufferLength = 512, TextLengthPtr = 0)
EXIT: SQL_SUCCESS = SQLGetDiagRec(HandleType = SQL_HANDLE_DBC, Handle = 0xc08110, RecNumber = 1, SQLState = HY092, NativeErrorPtr = -2130708341, MessageText = Invalid attribute/option identifier, BufferLength = 512, TextLengthPtr = 35)

This issue occurs under these conditions:

  • You use the Open Database Connectivity (ODBC) Driver that is provided by the SAS® Federation Server client.
  • The version number for the ODBC driver is 9403.100.22119.29796.

Click the Hot Fix tab in this note to access the hot fix for this issue.



Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SAS SystemSAS Federation ServerMicrosoft Windows 8 Enterprise 32-bit4.24.29.4 TS1M3
Microsoft Windows 8 Pro 32-bit4.24.29.4 TS1M3
Microsoft Windows 8.1 Enterprise 32-bit4.24.29.4 TS1M3
Microsoft Windows 8.1 Pro 32-bit4.24.29.4 TS1M3
Microsoft® Windows® for x644.24.29.4 TS1M39.4 TS1M3
Linux for x644.24.29.4 TS1M39.4 TS1M3