Problem Note 64049: You receive the message "ERROR: Numeric value out of range..." when loading a DB2 TIMESTAMP value into SASĀ® Cloud Analytic Services (CAS)
When loading a DB2 TIMESTAMP data type and the table contains a LONGVARCHAR data type, you can receive the following error:
ERROR: Numeric value out of range DATE_RESULT
ERROR: Function failed.
ERROR: The action stopped due to errors.
Click the Hot Fix tab in this note for a link to instructions about accessing and applying the software update.
After applying the hot fix, you can add the option INVALIDDATE= to your caslib. Here are the valid options:
WARN: Causes a warning when the row data is intact and the invalid date/timestamp is set to missing
SILENT: Causes the data to convert to missing and not give warnings or errors
ERROR: Causes an error
Operating System and Release Information
SAS System | SAS Data Connector to DB2 | Linux for x64 | V.03.03 | V.03.05 | Viya | Viya |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
Type: | Problem Note |
Priority: | high |
Date Modified: | 2019-04-29 16:33:57 |
Date Created: | 2019-04-17 09:59:31 |