Problem Note 62900: Uploading the out-of-the-box FCFWorkflow template through SAS® Workflow Studio in SAS® Anti-Money Laundering 6.3 fails with a warning message

DetailsAboutRate It

When you upload the sample FCFWorkflow.xml template that is provided in SAS Anti-Money Laundering 6.3 through SAS Workflow Studio, you see a warning message that is similar to the following:

Workflow error message

The workaround is to remove all of the following lines from the FCFWorkflow.xml template:

<sas_workflow_common:metadata>
  <sas_workflow_common:metadata_element>
  <sas_workflow_common:key>Drawing</sas_workflow_common:key>
  <sas_workflow_common:value><![CDATA[<?xml version="1.0" encoding="UTF-8"?>
    <process_plan>
      <nodes>
        <start_node>
          <size height="32" width="32" />
          <position>
            <point x="16" y="80" />
          </position>
          <connections portCount="4" />
        </start_node>
      </nodes>
    </process_plan>]]>   </sas_workflow_common:value>
  </sas_workflow_common:metadata_element>
</sas_workflow_common:metadata>


Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SAS SystemSAS Anti-Money LaunderingMicrosoft® Windows® for x646.36.3_M19.4 TS1M29.4 TS1M3
64-bit Enabled AIX6.36.3_M19.4 TS1M29.4 TS1M3
64-bit Enabled Solaris6.36.3_M19.4 TS1M29.4 TS1M3
Linux for x646.36.3_M19.4 TS1M29.4 TS1M3
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.