SUPPORT / SAMPLES & SAS NOTES
 

Support

Problem Note 61474: Using bulk loading with 32-bit SAS/ACCESS® Interface to PostgreSQL under Windows results in a missing "intl.dll" error

DetailsHotfixAboutRate It

In the latest release of the PostgreSQL client that shipped with SAS/ACCESS Interface to PostgreSQL, the libintl.dll library name changed to intl.dll. As a result, when trying to enable the bulk-load option from a 32-bit installation of SAS running under Windows, you might get the following error:

image label

This issue does not affect 64-bit SAS. 

A workaround is to rename the libintl.dll library currently included with the driver to intl.dll.

Click the Hot Fix tab in this note to access the hot fix for this issue.



Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SAS SystemSAS/ACCESS Interface to PostgreSQLMicrosoft Windows 8 Enterprise 32-bit9.4_M49.4_M69.4 TS1M49.4 TS1M6
Microsoft Windows 8 Pro 32-bit9.4_M49.4_M69.4 TS1M49.4 TS1M6
Microsoft Windows 8.1 Enterprise 32-bit9.4_M49.4_M69.4 TS1M49.4 TS1M6
Microsoft Windows 8.1 Pro 32-bit9.4_M49.4_M69.4 TS1M49.4 TS1M6
Windows 7 Enterprise 32 bit9.4_M49.4_M69.4 TS1M49.4 TS1M6
Windows 7 Home Premium 32 bit9.4_M49.4_M69.4 TS1M49.4 TS1M6
Windows 7 Professional 32 bit9.4_M49.4_M69.4 TS1M49.4 TS1M6
Windows 7 Ultimate 32 bit9.4_M49.4_M69.4 TS1M49.4 TS1M6
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.