SUPPORT / SAMPLES & SAS NOTES
 

Support

Problem Note 61230: Nested ABS functions cause SAS® Scalable Performance Data Server 5.3 to end abnormally

DetailsHotfixAboutRate It

When you use an SQL procedure with SAS Scalable Performance Data Server 5.3,  the server might stop abruptly and return the following error messages:

     ERROR: Error on server LIBNAME socket.

     ERROR: .

     ERROR: Client Generic Error - SocketWrite 

     ERROR: The tcpSockWrite call failed. The system error is 'Broken pipe'

The problem occurs if your PROC SQL query contains 13 or more nested absolute value (ABS) functions.

Workaround

Use IP=NO on your LIBNAME connection.

Click the Hot Fix tab in this note to access the hot fix for this issue.



Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SPDSSAS Scalable Peformance Data ServerMicrosoft® Windows® for x645.35.3 HF29.4 TS1M39.4 TS1M5
Microsoft Windows 105.35.3 HF29.4 TS1M39.4 TS1M5
64-bit Enabled AIX5.35.3 HF29.4 TS1M39.4 TS1M5
64-bit Enabled Solaris5.35.3 HF29.4 TS1M39.4 TS1M5
HP-UX IPF5.35.3 HF29.4 TS1M39.4 TS1M5
Linux for x645.35.3 HF29.4 TS1M39.4 TS1M5
Solaris for x645.35.3 HF29.4 TS1M39.4 TS1M5
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.