Problem Note 60273: A WARNING is issued for each row that is inserted into a Netezza temp table
A WARNING might be issued for each row that is processed by SAS/ACCESS® Interface to Netezza. This problem occurs when you use BULKLOAD to insert rows into a Netezza temp table accessed by a Netezza LIBNAME statement.
Code similar to the following can produce the WARNING:
libname x netezza server=nz-server user=user-ID pwd=password database=nz-db connection=global;
proc sql;
connect using x;
execute (create temp table ms_hhs2x (hhld_rtlr_cd varchar(20), hhld_id varchar(20), card_id varchar(20)) ) by x;
insert into x.ms_hhs2x (bulkload=yes )
select distinct hhld_rtlr_cd, hhld_id, card_id
from x.cust_v
where substr(card_id,10,2) ='49';
quit;
WARNING: Character expression will be truncated by the engine when assigned to character column HHLD_RTLR_CD
NOTE: 1 row was inserted into X.ms_hhs2x.
Although a WARNING is issued, the data is successfully inserted.
Click the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
| SAS System | SAS/ACCESS Interface to Netezza | Microsoft® Windows® for x64 | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Microsoft Windows 8 Enterprise 32-bit | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Microsoft Windows 8 Enterprise x64 | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Microsoft Windows 8 Pro 32-bit | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Microsoft Windows 8 Pro x64 | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Microsoft Windows 8.1 Enterprise 32-bit | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Microsoft Windows 8.1 Enterprise x64 | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Microsoft Windows 8.1 Pro 32-bit | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Microsoft Windows 8.1 Pro x64 | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Microsoft Windows 10 | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Microsoft Windows Server 2008 | 9.4_M3 | | 9.4 TS1M3 | |
| Microsoft Windows Server 2008 R2 | 9.4_M3 | | 9.4 TS1M3 | |
| Microsoft Windows Server 2008 for x64 | 9.4_M3 | | 9.4 TS1M3 | |
| Microsoft Windows Server 2012 Datacenter | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Microsoft Windows Server 2012 R2 Datacenter | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Microsoft Windows Server 2012 R2 Std | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Microsoft Windows Server 2012 Std | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Windows 7 Enterprise 32 bit | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Windows 7 Enterprise x64 | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Windows 7 Home Premium 32 bit | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Windows 7 Home Premium x64 | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Windows 7 Professional 32 bit | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Windows 7 Professional x64 | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Windows 7 Ultimate 32 bit | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Windows 7 Ultimate x64 | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| 64-bit Enabled AIX | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| 64-bit Enabled Solaris | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| HP-UX IPF | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
| Linux for x64 | 9.4_M3 | 9.42 | 9.4 TS1M3 | 9.4 TS1M5 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
A WARNING might be issued for each row that is processed by SAS/ACCESS® Interface to Netezza. This problem occurs when you use BULKLOAD to insert rows into a Netezza temp table accessed by the Netezza LIBNAME statement.
| Type: | Problem Note |
| Priority: | high |
| Date Modified: | 2017-04-14 09:37:47 |
| Date Created: | 2017-04-10 10:13:16 |