Problem Note 59479: You cannot modify inputs on the Input Mapping tab for DataFlux Data Service transformations
When connecting to a DataFlux® Data Management Server via SSL, you cannot add or modify inputs on the Input Mapping tab of the DataFlux Data Service transformation.
To enable modification, you must add the following parameters to the distudio.ini file, substituting values relevant to the keystore location and password on your system:
JavaArgs_16=-Djavax.net.ssl.trustStore=your-directory-path
JavaArgs_17=-Djavax.net.ssl.trustStorePassword=your-password
Note: If your directory path contains spaces, enclose it in quotation marks as shown here: JavaArgs_16=-Djavax.net.ssl.trustStore="your-directory-path".
Restart SAS® Data Integration Studio after making this change.
Operating System and Release Information
SAS System | SAS Data Integration Studio | Microsoft® Windows® for x64 | 4.9 | 4.902 | 9.4 TS1M0 | 9.4 TS1M5 |
Microsoft Windows 8 Enterprise x64 | 4.9 | 4.902 | 9.4 TS1M0 | 9.4 TS1M5 |
Microsoft Windows 8 Pro x64 | 4.9 | 4.902 | 9.4 TS1M0 | 9.4 TS1M5 |
Microsoft Windows 8.1 Enterprise 32-bit | 4.9 | 4.902 | 9.4 TS1M0 | 9.4 TS1M5 |
Microsoft Windows 8.1 Enterprise x64 | 4.9 | 4.902 | 9.4 TS1M0 | 9.4 TS1M5 |
Microsoft Windows 8.1 Pro 32-bit | 4.9 | 4.902 | 9.4 TS1M0 | 9.4 TS1M5 |
Microsoft Windows 8.1 Pro x64 | 4.9 | 4.902 | 9.4 TS1M0 | 9.4 TS1M5 |
Microsoft Windows 10 | 4.9 | 4.902 | 9.4 TS1M0 | 9.4 TS1M5 |
Microsoft Windows Server 2008 R2 | 4.9 | | 9.4 TS1M0 | |
Microsoft Windows Server 2008 for x64 | 4.9 | | 9.4 TS1M0 | |
Microsoft Windows Server 2012 Datacenter | 4.9 | 4.902 | 9.4 TS1M0 | 9.4 TS1M5 |
Microsoft Windows Server 2012 R2 Datacenter | 4.9 | 4.902 | 9.4 TS1M0 | 9.4 TS1M5 |
Microsoft Windows Server 2012 R2 Std | 4.9 | 4.902 | 9.4 TS1M0 | 9.4 TS1M5 |
Microsoft Windows Server 2012 Std | 4.9 | 4.902 | 9.4 TS1M0 | 9.4 TS1M5 |
Windows 7 Enterprise x64 | 4.9 | 4.902 | 9.4 TS1M0 | 9.4 TS1M5 |
Windows 7 Professional x64 | 4.9 | 4.902 | 9.4 TS1M0 | 9.4 TS1M5 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
When connecting to a DataFlux® Data Management Server over an SSL connection, the ability to modify inputs on the Input Mapping Tab is disabled.
Type: | Problem Note |
Priority: | high |
Date Modified: | 2016-12-08 13:05:25 |
Date Created: | 2016-12-07 15:41:46 |