Usage Note 57251: You encounter abend S0F4 Reason Code 24 for PDSE when the LRECL for the PDSE is greater than 4,096 bytes
Partitioned Data Set Extended (PDSE) RRI control structures are used when processing variable blocked
members. When the Logical Record Length (LRECL) for the PDSE is greater than one page size (4,096 bytes),
the algorithm within PDSE processing creates one RRI for each
record. The maximum cell pool size is 65,536 bytes. When the cell pool is
exhausted, an abend S0F4 with Reason Code 24 occurs.
The Output Delivery System (ODS) is commonly used to generate output to a member of a PDSE. When
using this method for output, sites should make sure that the LRECL for the PDSE is set properly for
their specific needs. For example, if it is creating HTML output, then the
LRECL for the PDSE should be no more than the length of the longest record plus
50 bytes as pad space for HTML tags.
Operating System and Release Information
| SAS System | N/A | z/OS 64-bit | | |
| z/OS | | |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
| Date Modified: | 2016-01-05 12:21:28 |
| Date Created: | 2015-12-14 09:22:16 |