Problem Note 56762: Updated decision-process definitions are not updated to the DS engine repository when a flow is redeployed from the design repository
In SAS® Real-Time Decision Manager, when you update a decision-process definition in the design server repository, the updates might not be present in the engine repository after a flow using that definition is redeployed. This issue only occurs when a previous version of the definition already exists in the engine repository.
To work around this issue, remove the activity metadata object from
the engine repository before redeploying the flow.
Click the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
SAS System | SAS Real-Time Decision Manager | Microsoft® Windows® for x64 | 6.4 | 6.5 | 9.4 TS1M2 | 9.4 TS1M3 |
64-bit Enabled AIX | 6.4 | 6.5 | 9.4 TS1M2 | 9.4 TS1M3 |
64-bit Enabled Solaris | 6.4 | 6.5 | 9.4 TS1M2 | 9.4 TS1M3 |
HP-UX IPF | 6.4 | 6.5 | 9.4 TS1M2 | 9.4 TS1M3 |
Linux for x64 | 6.4 | 6.5 | 9.4 TS1M2 | 9.4 TS1M3 |
Solaris for x64 | 6.4 | 6.5 | 9.4 TS1M2 | 9.4 TS1M3 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
Type: | Problem Note |
Priority: | high |
Date Modified: | 2015-11-20 11:02:47 |
Date Created: | 2015-10-09 15:32:05 |