Usage Note 55505: A "Load utility version is incompatible with Identity Column load" error occurs when you are using SAS/ACCESS® Interface to Teradata with FastLoad
When using SAS/ACCESS Interface to Teradata with FastLoad to insert data into a Teradata table, you might receive the following message:
ERROR: FastLoad failed the begin loading statement: Load utility version is incompatible with Identity Column load.
The problem occurs when you are using the Teradata FastLoad utility without the Teradata Parallel Transporter (TPT) to load into a Teradata identity column.
To circumvent the problem, specify the TPT=YES LIBNAME or DATA Set option in your code. Also, make sure that TPT is installed both on the client machine that is running SAS and on the Teradata server.
Operating System and Release Information
| SAS System | SAS/ACCESS Interface to Teradata | Microsoft® Windows® for x64 | 9.4 TS1M1 | |
| Microsoft Windows 8 Enterprise 32-bit | 9.4 TS1M1 | |
| Microsoft Windows 8 Enterprise x64 | 9.4 TS1M1 | |
| Microsoft Windows 8 Pro 32-bit | 9.4 TS1M1 | |
| Microsoft Windows 8 Pro x64 | 9.4 TS1M1 | |
| Microsoft Windows 8.1 Enterprise 32-bit | 9.4 TS1M1 | |
| Microsoft Windows 8.1 Enterprise x64 | 9.4 TS1M1 | |
| Microsoft Windows 8.1 Pro | 9.4 TS1M1 | |
| Microsoft Windows 8.1 Pro 32-bit | 9.4 TS1M1 | |
| Microsoft Windows Server 2008 | 9.4 TS1M1 | |
| Microsoft Windows Server 2008 R2 | 9.4 TS1M1 | |
| Microsoft Windows Server 2008 for x64 | 9.4 TS1M1 | |
| Microsoft Windows Server 2012 Datacenter | 9.4 TS1M1 | |
| Microsoft Windows Server 2012 R2 Datacenter | 9.4 TS1M1 | |
| Microsoft Windows Server 2012 R2 Std | 9.4 TS1M1 | |
| Microsoft Windows Server 2012 Std | 9.4 TS1M1 | |
| Windows 7 Enterprise 32 bit | 9.4 TS1M1 | |
| Windows 7 Enterprise x64 | 9.4 TS1M1 | |
| Windows 7 Home Premium 32 bit | 9.4 TS1M1 | |
| Windows 7 Home Premium x64 | 9.4 TS1M1 | |
| Windows 7 Professional 32 bit | 9.4 TS1M1 | |
| Windows 7 Professional x64 | 9.4 TS1M1 | |
| Windows 7 Ultimate 32 bit | 9.4 TS1M1 | |
| Windows 7 Ultimate x64 | 9.4 TS1M1 | |
| 64-bit Enabled AIX | 9.4 TS1M1 | |
| 64-bit Enabled Solaris | 9.4 TS1M1 | |
| HP-UX IPF | 9.4 TS1M1 | |
| Linux for x64 | 9.4 TS1M1 | |
| Solaris for x64 | 9.4 TS1M1 | |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
The error "FastLoad failed the begin loading statement: Load utility version is incompatible with Identity Column load" occurs when the Teradata Parallel Transporter (TPT) FastLoad is not installed. To circumvent the problem, use TPT.
| Date Modified: | 2015-05-12 15:27:37 |
| Date Created: | 2015-04-06 11:39:23 |