Problem Note 51048: Connecting to a metadata-defined SAS/SHARE® server using the XMS communication access method in a z/OS environment results in a system 0C6 abend
When you access a metadata-defined SAS/SHARE 9.3 server using the Cross-Memory Services (XMS) communication access method (the option COMAMID is set to XMS), a system 0C6 or 0C1 abend occurs in the SAS/SHARE server log along with traceback information similar to the following:
ERROR: System abend 0C6 occurred in module FLMS7C function SecurityGetProvid
ERROR: Traceback will be attempted...
NOTE: Traceback called
NOTE: Module Function Offset Line
NOTE: -------- -------- ------ ----
NOTE: SASYHRSV YHRCACP 0002A2 0
NOTE: SASYHRSV YHRMRIO 00032A 0
NOTE: SASYHRSV @@588148 000068 0 yhrsa_inf
NOTE: SASYHRWT SASYHRWT 000334 0
NOTE: SASHOST UNKNOWN 002DD0 0
Work task SHRWTSK2 has been terminated. In "OPERATE"
TERMINATE WORK TASK: Unexpected ERROR 8000301F from
ERROR: Delete current task.
The following error occurs in the client log:
ERROR: Attempt to connect to server xxxxxxxx rejected by server.
ERROR: Delete current task.
Click the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
SAS System | SAS/SHARE | z/OS | 9.3 | 9.3 | 9.3 TS1M0 | 9.4 TS1M0 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
Type: | Problem Note |
Priority: | high |
Date Modified: | 2013-10-10 13:13:25 |