Problem Note 49065: Submitting selected code to SAS® Grid Computing produces application error "The library SASCATCA on server SASApp was not found"

DetailsHotfixAboutRate It
SAS® Enterprise Guide® 5.1 users might intermittently receive the following error when submitting selected code to a SAS® Grid Computing environment.
The library SASCATCA on server SASApp was not found. -------------------------- Technical Information Follows-------------------------- Exception Details: ---------------------------------------- Exception type: SAS.Shared.Exceptions.ObjectNotFoundException Message: The library SASCATCA on server SASApp was not found. Source: SAS.EG.SDS.Model Target Site: GetLibrary

This error can occur under the following circumstances:

  • When SAS Enterprise Guide has not connected to the SAS grid beforehand
  • When a specific code selection is submitted from within the SAS Enterprise Guide Program Editor
  • When the submitted SAS Enterprise Guide program creates output data sets
  • When the SAS Enterprise Guide program has been run previously, and generated output data sets are contained in the process flow

To work around the issue, do the following prior to a run selection:

  1. Open the server list and select the server.
  2. Select Connect to Grid.

Click the Hot Fix tab in this note to access the hot fix for this issue.



Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SAS SystemSAS Enterprise GuideMicrosoft® Windows® for x645.16.19.3 TS1M2
Microsoft Windows 8 Pro5.1
Microsoft Windows Server 2003 Datacenter Edition5.16.19.3 TS1M2
Microsoft Windows Server 2003 Enterprise Edition5.16.19.3 TS1M2
Microsoft Windows Server 2003 Standard Edition5.16.19.3 TS1M2
Microsoft Windows Server 2003 for x645.16.19.3 TS1M2
Microsoft Windows Server 20085.16.19.3 TS1M2
Microsoft Windows Server 2008 for x645.16.19.3 TS1M2
Microsoft Windows Server 20125.1
Microsoft Windows XP Professional5.16.19.3 TS1M2
Windows 7 Enterprise 32 bit5.16.19.3 TS1M2
Windows 7 Enterprise x645.16.19.3 TS1M2
Windows 7 Home Premium 32 bit5.16.19.3 TS1M2
Windows 7 Home Premium x645.16.19.3 TS1M2
Windows 7 Professional 32 bit5.16.19.3 TS1M2
Windows 7 Professional x645.16.19.3 TS1M2
Windows 7 Ultimate 32 bit5.16.19.3 TS1M2
Windows 7 Ultimate x645.16.19.3 TS1M2
Windows Millennium Edition (Me)5.1
Windows Vista5.16.19.3 TS1M2
Windows Vista for x645.16.19.3 TS1M2
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.