Problem Note 48439: Global macro variables are incorrectly set within a workspace server
When creating macro variables within a Workspace server, the SAS Macro Facility incorrectly places a new macro variable, with the same name, in the wrong scope. The code to display all GLOBAL macro variables was also at times using the incorrect scope name when listing variables.
The workaround for this is to avoid using macro parameters with the same names as global macro variables.
Operating System and Release Information
SAS System | Base SAS | z/OS | 9.2 TS2M3 | 9.4 TS1M0 |
Microsoft® Windows® for 64-Bit Itanium-based Systems | 9.2 TS2M3 | 9.4 TS1M0 |
Microsoft Windows Server 2003 Datacenter 64-bit Edition | 9.2 TS2M3 | 9.4 TS1M0 |
Microsoft Windows Server 2003 Enterprise 64-bit Edition | 9.2 TS2M3 | 9.4 TS1M0 |
Microsoft Windows XP 64-bit Edition | 9.2 TS2M3 | 9.4 TS1M0 |
Microsoft® Windows® for x64 | 9.2 TS2M3 | 9.4 TS1M0 |
Microsoft Windows Server 2003 Datacenter Edition | 9.2 TS2M3 | 9.4 TS1M0 |
Microsoft Windows Server 2003 Enterprise Edition | 9.2 TS2M3 | 9.4 TS1M0 |
Microsoft Windows Server 2003 Standard Edition | 9.2 TS2M3 | 9.4 TS1M0 |
Microsoft Windows Server 2003 for x64 | 9.2 TS2M3 | 9.4 TS1M0 |
Microsoft Windows Server 2008 | 9.2 TS2M3 | 9.4 TS1M0 |
Microsoft Windows Server 2008 for x64 | 9.2 TS2M3 | 9.4 TS1M0 |
Microsoft Windows XP Professional | 9.2 TS2M3 | 9.4 TS1M0 |
Windows 7 Enterprise 32 bit | 9.2 TS2M3 | 9.4 TS1M0 |
Windows 7 Enterprise x64 | 9.2 TS2M3 | 9.4 TS1M0 |
Windows 7 Home Premium 32 bit | 9.2 TS2M3 | 9.4 TS1M0 |
Windows 7 Home Premium x64 | 9.2 TS2M3 | 9.4 TS1M0 |
Windows 7 Professional 32 bit | 9.2 TS2M3 | 9.4 TS1M0 |
Windows 7 Professional x64 | 9.2 TS2M3 | 9.4 TS1M0 |
Windows 7 Ultimate 32 bit | 9.2 TS2M3 | 9.4 TS1M0 |
Windows 7 Ultimate x64 | 9.2 TS2M3 | 9.4 TS1M0 |
Windows Vista | 9.2 TS2M3 | 9.4 TS1M0 |
Windows Vista for x64 | 9.2 TS2M3 | 9.4 TS1M0 |
64-bit Enabled AIX | 9.2 TS2M3 | 9.4 TS1M0 |
64-bit Enabled HP-UX | 9.2 TS2M3 | 9.4 TS1M0 |
64-bit Enabled Solaris | 9.2 TS2M3 | 9.4 TS1M0 |
HP-UX IPF | 9.2 TS2M3 | 9.4 TS1M0 |
Linux | 9.2 TS2M3 | 9.4 TS1M0 |
Linux for x64 | 9.2 TS2M3 | 9.4 TS1M0 |
OpenVMS on HP Integrity | 9.2 TS2M3 | 9.4 TS1M0 |
Solaris for x64 | 9.2 TS2M3 | 9.4 TS1M0 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
Creating a macro variable within a workspace server can cause the macro variable to be written to the wrong scope.
Type: | Problem Note |
Priority: | low |
Date Modified: | 2012-11-09 11:06:35 |
Date Created: | 2012-11-09 09:06:49 |