SUPPORT / SAMPLES & SAS NOTES
 

Support

Problem Note 47171: Running performance monitoring reports on a champion Scorecard model returns syntax errors

DetailsHotfixAboutRate It

In SAS® Model Manager, you might receive the following error message when running a performance monitoring report:

NOTE: Line generated by the invoked macro "MM_CHECKPERFORMANCEINPUT".
17833 proc contents data = &inds out = work.contents(keep = name length type);
                                             _
                                             22
                                             76

ERROR 22-322: Syntax error, expecting one of the following: DATA, OUT, OUT2. 

ERROR 76-322: Syntax error, statement will be ignored.

This error might occur when you have the following scenario:

  • You imported a Scorecard model from SAS® Enterprise Miner™.
  • You set the Scorecard model as the Champion model.

There is no workaround for this issue.

Click the Hot Fix tab in this note to access the hot fix for this issue.



Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SAS SystemSAS Model ManagerMicrosoft® Windows® for x643.13.1_M19.3 TS1M09.3 TS1M1
Microsoft Windows Server 2003 Datacenter Edition3.13.1_M19.3 TS1M09.3 TS1M1
Microsoft Windows Server 2003 Enterprise Edition3.13.1_M19.3 TS1M09.3 TS1M1
Microsoft Windows Server 2003 Standard Edition3.13.1_M19.3 TS1M09.3 TS1M1
Microsoft Windows Server 2003 for x643.13.1_M19.3 TS1M09.3 TS1M1
Microsoft Windows Server 20083.13.1_M19.3 TS1M09.3 TS1M1
Microsoft Windows Server 2008 for x643.13.1_M19.3 TS1M09.3 TS1M1
Microsoft Windows XP Professional3.13.1_M19.3 TS1M09.3 TS1M1
Windows 7 Enterprise 32 bit3.13.1_M19.3 TS1M09.3 TS1M1
Windows 7 Enterprise x643.13.1_M19.3 TS1M09.3 TS1M1
Windows 7 Home Premium 32 bit3.13.1_M19.3 TS1M09.3 TS1M1
Windows 7 Home Premium x643.13.1_M19.3 TS1M09.3 TS1M1
Windows 7 Professional 32 bit3.13.1_M19.3 TS1M09.3 TS1M1
Windows 7 Professional x643.13.1_M19.3 TS1M09.3 TS1M1
Windows 7 Ultimate 32 bit3.13.1_M19.3 TS1M09.3 TS1M1
Windows 7 Ultimate x643.13.1_M19.3 TS1M09.3 TS1M1
64-bit Enabled AIX3.13.1_M19.3 TS1M09.3 TS1M1
64-bit Enabled Solaris3.13.1_M19.3 TS1M09.3 TS1M1
HP-UX IPF3.13.1_M19.3 TS1M09.3 TS1M1
Linux for x643.13.1_M19.3 TS1M09.3 TS1M1
Solaris for x643.13.1_M19.3 TS1M09.3 TS1M1
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.