SUPPORT / SAMPLES & SAS NOTES
 

Support

Problem Note 46731: SAS® 9.3 terminates unexpectedly when you clear the Output window

DetailsHotfixAboutRate It

SAS 9.3 for Microsoft Windows operating systems terminates unexpectedly when you clear the Output window. The problem occurs after you run certain interactive procedures without a QUIT statement to terminate the procedure. Some common interactive procedures with which this issue occurs are PROC REG, PROC GLM, PROC ARIMA, PROC SQL, and PROC CATMOD. However, you might see the problem with other interactive procedures as well.

Note that SAS will terminate differently based on whether the SAS installation is for a 32-bit or 64-bit system:

  • For 32-bit SAS installations, a window containing the following message appears:
  • SAS.EXE has stopped working.
  • For 64-bit SAS installations, SAS terminates unexpectedly with no error or warning.

The problem occurs when the following option has been set under Preferences in SAS: On the Results tab (from Tools ► Options ►Preferences) the Create listing and View results as they are generated check boxes have been selected and the other items on the Results tab remain unchecked.

Workarounds

To circumvent the problem, do any of the following:

  • Make sure that a QUIT; statement follows the procedure.
  • Or change this preference on the Preferences tab: Deselect the Create listing check box and select the Create HTML check box instead.
  • Or apply the hot fix for this issue.

Click the Hot Fix tab in this note to access the hot fix for this issue.



Operating System and Release Information

Product FamilyProductSystemSAS Release
ReportedFixed*
SAS SystemBase SASWindows 7 Ultimate 32 bit9.3 TS1M1
Windows 7 Professional x649.3 TS1M19.4 TS1M0
Microsoft Windows Server 20089.3 TS1M1
Microsoft Windows Server 2008 for x649.3 TS1M19.4 TS1M0
Microsoft Windows XP Professional9.3 TS1M1
Windows 7 Enterprise 32 bit9.3 TS1M1
Windows 7 Enterprise x649.3 TS1M19.4 TS1M0
Windows 7 Home Premium 32 bit9.3 TS1M1
Windows 7 Home Premium x649.3 TS1M1
Windows 7 Professional 32 bit9.3 TS1M1
Microsoft® Windows® for x649.3 TS1M19.4 TS1M0
Microsoft Windows Server 2003 Datacenter Edition9.3 TS1M1
Microsoft Windows Server 2003 Enterprise Edition9.3 TS1M1
Microsoft Windows Server 2003 Standard Edition9.3 TS1M1
Microsoft Windows Server 2003 for x649.3 TS1M1
Windows 7 Ultimate x649.3 TS1M1
Windows Vista9.3 TS1M1
Windows Vista for x649.3 TS1M1
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.