Problem Note 46319: Cannot build location analytical hierarchy

DetailsAboutRate It

When attempting to build the location analytical hierarchy in the SAS® Merchandise Solutions Configuration Workbench for SAS® High-Performance Markdown Optimization, you might notice the hierarchy is not built and the following error will be visible in the workspace server log:

NOTE: Table WORK.STD_LEVELS_BELOW_ATTR created, with 2 rows and 1 columns.

NOTE: PROCEDURE SQL used (Total process time):
      real time           0.00 seconds
      cpu time            0.00 seconds
      

explicitly turning off mprint and notes
ERROR: The variable prod_id in the DROP, KEEP, or RENAME list has never been referenced.

NOTE: Character values have been converted to numeric values at the places given by: (Line):(Column).
      1:3   
NOTE: The SAS System stopped processing this step because of errors.
WARNING: The data set WORK.GP_DM_MID2 may be incomplete.  When this step was stopped there were 0 observations and 5 variables.
NOTE: DATA statement used (Total process time):
      real time           0.03 seconds
      cpu time            0.00 seconds

The software will not allow you to build a location hierarchy with multiple attributes if you sandwich standard levels between attributes. A hierarchy pattern containing standard (S) and attribute (A) levels in the form S-A-A-A-A-S can be build, but a hierarchy of the form S-A-S-S-A-S cannot be built. The workaround for this issue is to create attributes for those standard levels that you wish to place between attribute levels in your analytical location hierarchy.



Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SAS SystemSAS High-Performance Markdown OptimizationLinux for x644.3_M25.29.2 TS2M39.3 TS1M0
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.