Problem Note 44235: ERROR: TKTException code = 10 (Domain exception)
Running optimization on SAS
®: High-Performance Optimization, can fail if Post-plan markdowns
are enabled for plans being optimized. This is due to the improper allocation of memory for each
MDO_PROD_GEO object.
Th error manifests itself in the HiPerfMerchIntelGridSvr.log as:
ERROR: TKTException code = 10 (Domain exception)
The workaround is to uncheck Post-plan markdowns for each plan.
Click the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
SAS System | SAS High-Performance Markdown Optimization | Microsoft® Windows® for x64 | 4.3_M1 | 4.3_M2 | 9.2 TS2M3 | 9.2 TS2M3 |
Linux for x64 | 4.3_M1 | 4.3_M2 | 9.2 TS2M3 | 9.2 TS2M3 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
Type: | Problem Note |
Priority: | medium |
Date Modified: | 2011-09-19 09:16:13 |
Date Created: | 2011-09-07 15:27:08 |