Installation Note 43369: The error "Could not read configuration file... webinfpltfm_ExportDatabase_log4j.config" occurs while you are performing a migration in SAS® 9.2
When you are performing a migration in SAS 9.2, the error shown below might occur in your migration.log file.
If this error does occur, you may ignore it. The data is exported successfully despite this error.
[INFO ] SMU {biservmid.Execute.echo} Exporting database 'SharedServices'
[INFO ] SMU {biservmid.Execute.echo} The process used to export the
SharedServices database will log to the /smu_output_biservmid_only/
foo.xxx.xx.com/biservmid/webinfpltfm_ExportDatabase.log file.
[INFO ] SMU {biservmid.Execute.echo} ExportDatabase return code: 0
[INFO ] SMU {biservmid.Execute.echo} ExportDatabase output:
log4j:ERROR Could not read configuration file
[file:////smu_output_biservmid_only/foo.xxx.xx.com/biservmid/
webinfpltfm_ExportDatabase_log4j.config].
java.io.FileNotFoundException: file:/smu_output_biservmid_only/foo.xxx.xx.com/
biservmid/webinfpltfm_ExportDatabase_log4j.config (EDC5129I No such file or
directory.)
at java.io.FileInputStream.(FileInputStream.java:123)
at java.io.FileInputStream.(FileInputStream.java:83)
at
org.apache.log4j.PropertyConfigurator.doConfigure(PropertyConfigurator.java:306)
at
org.apache.log4j.PropertyConfigurator.configure(PropertyConfigurator.java:324)
at com.sas.tkts.logger.TSLogger4j.(TSLogger4j.java:22)
at com.sas.tkts.logger.TSLoggerFactory.getLogger(TSLoggerFactory.java:28)
at com.sas.tkts.TKTSDriver.(TKTSDriver.java:70)
at java.lang.J9VMInternals.initializeImpl(Native Method)
at java.lang.J9VMInternals.initialize(J9VMInternals.java:200)
at java.lang.Class.forNameImpl(Native Method)
at java.lang.Class.forName(Class.java:139)
at
com.sas.smu.webinfpltfm.DbConnectionFactory.loadDriver(DbConnectionFactory.java:
198)
at
com.sas.smu.webinfpltfm.DbConnectionFactory.newConnection(DbConnectionFactory.ja
va:114)
at com.sas.smu.webinfpltfm.DbExporterFactory.main(DbExporterFactory.java:217)
log4j:ERROR Ignoring configuration file [file:////smu_output_biservmid_only/
foo.xxx.xx.com/biservmid/webinfpltfm_ExportDatabase_log4j.config].
[INFO ] SMU {biservmid.Execute.echo} Database 'SharedServices' has been
exported to /smu_output_biservmid_only/foo.xxx.xx.com/biservmid/WIP_database.zip
[INFO ] SMU Project biservmid completed.
[INFO ] SMU Product analyses completed: 1
[INFO ] SMU Product packaging completed: 1
This was fixed with SAS 9.3 (TS1M2) with revision 13w05 released in January 2013.
Operating System and Release Information
SAS System | SAS Migration Utility for 9.1.3 | z/OS | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Microsoft® Windows® for 64-Bit Itanium-based Systems | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Microsoft Windows Server 2003 Datacenter 64-bit Edition | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Microsoft Windows Server 2003 Enterprise 64-bit Edition | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Microsoft Windows 95/98 | 9.1.3.10 | | | |
Microsoft Windows 2000 Advanced Server | 9.1.3.10 | | | |
Microsoft Windows 2000 Datacenter Server | 9.1.3.10 | | | |
Microsoft Windows 2000 Server | 9.1.3.10 | | | |
Microsoft Windows 2000 Professional | 9.1.3.10 | | | |
Microsoft Windows NT Workstation | 9.1.3.10 | | | |
Microsoft Windows Server 2003 Datacenter Edition | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Microsoft Windows Server 2003 Enterprise Edition | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Microsoft Windows Server 2003 Standard Edition | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Microsoft Windows Server 2003 for x64 | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Microsoft Windows Server 2008 | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Microsoft Windows Server 2008 for x64 | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Microsoft Windows XP Professional | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Windows 7 Enterprise 32 bit | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Windows 7 Enterprise x64 | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Windows 7 Home Premium 32 bit | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Windows 7 Home Premium x64 | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Windows 7 Professional 32 bit | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Windows 7 Professional x64 | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Windows 7 Ultimate 32 bit | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Windows 7 Ultimate x64 | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Windows Millennium Edition (Me) | 9.1.3.10 | | | |
Windows Vista | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Windows Vista for x64 | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
64-bit Enabled AIX | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
64-bit Enabled HP-UX | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
64-bit Enabled Solaris | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
HP-UX IPF | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Linux | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Linux on Itanium | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
Solaris for x64 | 9.1.3.10 | 9.1.3.10 | | 9.3 TS1M0 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
Type: | Installation Note |
Priority: | high |
Date Modified: | 2013-07-22 14:43:11 |
Date Created: | 2011-05-27 11:47:11 |