Problem Note 41593: Fractional seconds are not written properly to Netezza when you use the BULKLOAD=YES option
When you use the BULKLOAD=YES option to load a SAS data set to Netezza, fractional seconds in a datetime value are not written properly. For example, suppose you have the following DATETIME25.6 value:
2009-01-19 09:55:05.123456
When you use the BULKLOAD=YES option, that date is written such that the last three digits are converted to zeros:
2009-01-19 09:55:05.123000
If you do not specify BULKLOAD=YES, the data is written properly.
Click the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
| SAS System | SAS/ACCESS Interface to Netezza | Microsoft® Windows® for x64 | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Microsoft Windows Server 2003 Datacenter Edition | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Microsoft Windows Server 2003 Enterprise Edition | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Microsoft Windows Server 2003 Standard Edition | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Microsoft Windows Server 2003 for x64 | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Microsoft Windows Server 2008 | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Microsoft Windows Server 2008 for x64 | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Microsoft Windows XP Professional | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Windows 7 Enterprise 32 bit | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Windows 7 Enterprise x64 | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Windows 7 Home Premium 32 bit | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Windows 7 Home Premium x64 | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Windows 7 Professional 32 bit | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Windows 7 Professional x64 | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Windows 7 Ultimate 32 bit | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Windows 7 Ultimate x64 | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Windows Vista | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Windows Vista for x64 | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| 64-bit Enabled AIX | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| 64-bit Enabled HP-UX | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| 64-bit Enabled Solaris | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| HP-UX IPF | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Linux | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
| Linux for x64 | 9.22_M2 | 9.22_M2 | 9.2 TS2M3 | 9.3 TS1M0 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
| Type: | Problem Note |
| Priority: | medium |
| Topic: | Data Management ==> Data Sources ==> External Databases ==> Netezza
|
| Date Modified: | 2010-11-17 10:17:34 |
| Date Created: | 2010-11-15 08:44:19 |