SUPPORT / SAMPLES & SAS NOTES
 

Support

Problem Note 40213: The file or directory name is not displayed entirely in the prompt field on the Parameters Web page for a SAS® Stored Process executed in a Web client

DetailsAboutRate It

When you execute a SAS® Stored Process from a Web client, the prompt field for a file or directory name on the Parameters Web page is set at a fixed length. As a result, the entire name of the selected file or directory might not appear:

File or Directory prompt field length is limited

Note: The full name of the file or directory still populates the input field and passes to the SAS session in its entirety.

This issue occurs only when the prompt for the file or directory name is generated by SAS. An option to increase the size of this prompt that is generated by SAS is not available. For more information about prompt pages, see Using the SAS Stored Process Web Application Pages: Prompt Page in the SAS® 9.4 Stored Processes: Developer’s Guide, Third Edition.

However, you can create a custom input form that has a wider field for the file or directory name. For example, include the <INPUT> tag for the custom input form, as follows:

<input type=file name=filenm size=100>

For more information about creating and using custom input forms, see SAS Note 38621, "Tips for creating a Custom Input Form for a SAS® Stored Process."



Operating System and Release Information

Product FamilyProductSystemSAS Release
ReportedFixed*
SAS SystemSAS Integration Technologiesz/OS9.2 TS2M09.3 TS1M0
Microsoft® Windows® for 64-Bit Itanium-based Systems9.2 TS2M09.3 TS1M0
Microsoft Windows Server 2003 Datacenter 64-bit Edition9.2 TS2M09.3 TS1M0
Microsoft Windows Server 2003 Enterprise 64-bit Edition9.2 TS2M09.3 TS1M0
Microsoft Windows XP 64-bit Edition9.2 TS2M09.3 TS1M0
Microsoft® Windows® for x649.2 TS2M09.3 TS1M0
Microsoft Windows Server 2003 Datacenter Edition9.2 TS2M09.3 TS1M0
Microsoft Windows Server 2003 Enterprise Edition9.2 TS2M09.3 TS1M0
Microsoft Windows Server 2003 Standard Edition9.2 TS2M09.3 TS1M0
Microsoft Windows Server 2003 for x649.2 TS2M09.3 TS1M0
Microsoft Windows Server 2008 for x649.2 TS2M09.3 TS1M0
Microsoft Windows XP Professional9.2 TS2M09.3 TS1M0
Windows Vista9.2 TS2M09.3 TS1M0
Windows Vista for x649.2 TS2M09.3 TS1M0
64-bit Enabled AIX9.2 TS2M09.3 TS1M0
64-bit Enabled HP-UX9.2 TS2M09.3 TS1M0
64-bit Enabled Solaris9.2 TS2M09.3 TS1M0
HP-UX IPF9.2 TS2M09.3 TS1M0
Linux9.2 TS2M09.3 TS1M0
Linux for x649.2 TS2M09.3 TS1M0
OpenVMS on HP Integrity9.2 TS2M09.3 TS1M0
Solaris for x649.2 TS2M09.3 TS1M0
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.