SUPPORT / SAMPLES & SAS NOTES
 

Support

Problem Note 37357: A job stops executing, but remains active in the queue when you start the SFB_HMDA_JOB_DRIVER and SFB_CRA_JOB_DRIVER macros

DetailsHotfixAboutRate It

The SFB_HMDA_JOB_DRIVER and SFB_CRA_JOB_DRIVER macros require a SUB_YEAR parameter when you submit a job. If you do not supply the parameter when you call either of these macros, the job stops, but it remains in the job queue as an active job. You are unable to execute that job until you remove the job from the queue. There is no tool available to clean up the queue.

As a workaround, you can manually delete the record for the job from the Cntl.Job_Queue data set and restart the macro with the SUB_YEAR parameter included.

Click the Hot Fix tab in this note to access the hot fix for this issue.



Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SAS SystemSAS Fair Banking ServerMicrosoft Windows Server 2003 Datacenter Edition4.14.29.2 TS2M09.2 TS2M2
Microsoft Windows Server 2003 Enterprise Edition4.14.29.2 TS2M09.2 TS2M2
Microsoft Windows Server 2003 Standard Edition4.14.29.2 TS2M09.2 TS2M2
64-bit Enabled AIX4.14.29.2 TS2M09.2 TS2M2
64-bit Enabled Solaris4.14.29.2 TS2M09.2 TS2M2
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.