Problem Note 36315: Printing from SAS/INSIGHT® writes errors to the SAS Log and shuts down the SAS® Display Manager System
Printing output from SAS/INSIGHT writes error messages to the SAS Log and then shuts down the SAS Display Manager System (DMS). If you capture the SAS Log output to a disk file, the captured error messages start with the following:
FATAL ERROR: WRCODE=8000480C, MODULE='vupRemoveLCB': Attempt to
destroy a WU resource not owned by the REB
Traceback
SASTBTraceBackCtx has been called with a
string ("vacrash") instead of a CONTEXT pointer.
Address Frame (DBGHELP API Version 4.0 rev 5)
4FD32EB8 06C9C06C tkmk:tkBoot+0x31E94
To circumvent the problem, change the font that SAS/INSIGHT uses to a font other than the default. The default font is named Sasfont.
To change the font that SAS/INSIGHT uses, make the SAS Log window the active window. From the Display Manager System's pull-down options menu, select Tools => Options => Fonts...
Next, choose a font other than Sasfont, such as Courier New or SAS Monospace. Click OK. At this point, SAS/INSIGHT will use the same font that the SAS Log window uses. To save this font change for future SAS sessions, with the SAS Log window the active window, issue the following DMS command:
After changing the font, printing from SAS/INSIGHT now works correctly.
Operating System and Release Information
SAS System | SAS/INSIGHT | Microsoft Windows Server 2003 Datacenter 64-bit Edition | 9.2 TS1M0 | 9.2 TS2M0 |
Microsoft Windows Server 2003 Enterprise 64-bit Edition | 9.2 TS1M0 | 9.2 TS2M0 |
Microsoft Windows XP 64-bit Edition | 9.2 TS1M0 | 9.2 TS2M0 |
Microsoft® Windows® for x64 | 9.2 TS1M0 | 9.2 TS2M0 |
Microsoft Windows Server 2003 Datacenter Edition | 9.2 TS1M0 | 9.2 TS2M0 |
Microsoft® Windows® for 64-Bit Itanium-based Systems | 9.2 TS1M0 | 9.2 TS2M0 |
Microsoft Windows Server 2003 Enterprise Edition | 9.2 TS1M0 | 9.2 TS2M0 |
Microsoft Windows Server 2003 Standard Edition | 9.2 TS1M0 | 9.2 TS2M0 |
Microsoft Windows XP Professional | 9.2 TS1M0 | 9.2 TS2M0 |
Windows Vista | 9.2 TS1M0 | 9.2 TS2M0 |
64-bit Enabled AIX | 9.2 TS1M0 | 9.2 TS2M0 |
64-bit Enabled HP-UX | 9.2 TS1M0 | 9.2 TS2M0 |
64-bit Enabled Solaris | 9.2 TS1M0 | 9.2 TS2M0 |
HP-UX IPF | 9.2 TS1M0 | 9.2 TS2M0 |
Linux | 9.2 TS1M0 | 9.2 TS2M0 |
Linux for x64 | 9.2 TS1M0 | 9.2 TS2M0 |
OpenVMS on HP Integrity | 9.2 TS1M0 | 9.2 TS2M0 |
Solaris for x64 | 9.2 TS1M0 | 9.2 TS2M0 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
Printing from SAS/INSIGHT® writes errors to the SAS Log and then shuts down the SAS® Display Manager System.
Type: | Problem Note |
Priority: | medium |
Date Modified: | 2009-06-23 10:42:14 |
Date Created: | 2009-06-22 15:16:14 |