Problem Note 35817: In SAS® Warranty Analysis Emerging Issues, it is not possible to access more than 50 alerts, and an exception error occurs if you scroll the page

DetailsHotfixAboutRate It

In Emerging Issues, it is not possible to display and access more than 50 alerts. Paging is not enabled and results in a Java OutOfBounds error:

java.lang.IndexOutOfBoundsException: Page number out of bounds: 2

You would see an error message like the following:

errorimage

A workaround is to increase the number of alerts that can be displayed per page so they fit on a single page. To increase the number of alerts displayed per page:

  1. Edit the landingPage.config file in the directory. For example, edit webapps\SASWarrantyAnalysis\WEB-INF\conf and modify the value for the property eiTableRowPageSizeValue
  2. Restart the SAS Warranty Analysis Web application.

Select the Hot Fix tab in this note to access the hot fix for this issue.



Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SAS SystemSAS Warranty AnalysisMicrosoft Windows Server 2003 Datacenter Edition4.14.29.1 TS1M3 SP49.2 TS2M2
64-bit Enabled AIX4.14.29.1 TS1M3 SP49.2 TS2M2
Microsoft Windows Server 2003 Standard Edition4.14.29.1 TS1M3 SP49.2 TS2M2
Microsoft Windows Server 2003 Enterprise Edition4.14.29.1 TS1M3 SP49.2 TS2M2
64-bit Enabled Solaris4.14.29.1 TS1M3 SP49.2 TS2M2
HP-UX IPF4.14.29.1 TS1M3 SP49.2 TS2M2