SUPPORT / SAMPLES & SAS NOTES
 

Support

Problem Note 34732: Changing bins in the Fine Detail tab of an Interval Input Variables selection causes truncation and duplication of values

DetailsHotfixAboutRate It

In the SAS® Enterprise Miner™ Interactive Grouping node, merging or splitting a bin for an interval input variable in the Fine Detail tab interactive window will change the length of the _split_value_ variable. If you have only interval variables, this is not a problem.

However, if you select a nominal input variable for interactive grouping on the Fine Detail tab after you select an interval input variable for interactive grouping on the Fine Detail tab, the node will create two sets of incorrect bins for the nominal variable. The first set of bins will contain the original values. The second set of bins will contain truncated values.

Select the Hot Fix tab in this note to access the hot fix for this issue.



Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SAS SystemSAS Enterprise MinerMicrosoft® Windows® for 64-Bit Itanium-based Systems5.36.19.1 TS1M3 SP49.2 TS2M0
Microsoft Windows Server 2003 Datacenter 64-bit Edition5.36.19.1 TS1M3 SP49.2 TS2M0
Microsoft Windows Server 2003 Enterprise 64-bit Edition5.36.19.1 TS1M3 SP49.2 TS2M0
Microsoft Windows XP 64-bit Edition5.36.19.1 TS1M3 SP49.2 TS2M0
Microsoft® Windows® for x645.36.19.1 TS1M3 SP49.2 TS2M0
Microsoft Windows 2000 Advanced Server5.39.1 TS1M3 SP4
Microsoft Windows 2000 Datacenter Server5.39.1 TS1M3 SP4
Microsoft Windows 2000 Server5.39.1 TS1M3 SP4
Microsoft Windows 2000 Professional5.39.1 TS1M3 SP4
Microsoft Windows NT Workstation5.39.1 TS1M3 SP4
Microsoft Windows Server 2003 Datacenter Edition5.36.19.1 TS1M3 SP49.2 TS2M0
Microsoft Windows Server 2003 Enterprise Edition5.36.19.1 TS1M3 SP49.2 TS2M0
Microsoft Windows Server 2003 Standard Edition5.36.19.1 TS1M3 SP49.2 TS2M0
Microsoft Windows XP Professional5.36.19.1 TS1M3 SP49.2 TS2M0
64-bit Enabled AIX5.36.19.1 TS1M3 SP49.2 TS2M0
64-bit Enabled HP-UX5.36.19.1 TS1M3 SP49.2 TS2M0
64-bit Enabled Solaris5.36.19.1 TS1M3 SP49.2 TS2M0
HP-UX IPF5.36.19.1 TS1M3 SP49.2 TS2M0
Linux5.36.19.1 TS1M3 SP49.2 TS2M0
Linux on Itanium5.36.19.1 TS1M3 SP49.2 TS2M0
Solaris for x645.36.19.1 TS1M3 SP49.2 TS2M0
Tru64 UNIX5.36.19.1 TS1M3 SP49.2 TS2M0
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.