Using the metadata LIBNAME engine (META) with the METAOUT=DATA option might cause the PROC OLAP code that is used to build a cube to fail. This is because the procedure might mistakenly interpret a note from the library being opened as an error.
Using the METAOUT=ALL option will avoid this problem.
Product Family | Product | System | SAS Release | |
Reported | Fixed* | |||
SAS System | SAS OLAP Server | z/OS | 9.1 TS1M0 | 9.2 TS2M3 |
Microsoft® Windows® for 64-Bit Itanium-based Systems | 9.1 TS1M0 | |||
Microsoft Windows Server 2003 Datacenter 64-bit Edition | 9.1 TS1M0 | |||
Microsoft Windows Server 2003 Enterprise 64-bit Edition | 9.1 TS1M0 | |||
Microsoft Windows 2000 Advanced Server | 9.1 TS1M0 | |||
Microsoft Windows 2000 Datacenter Server | 9.1 TS1M0 | |||
Microsoft Windows 2000 Server | 9.1 TS1M0 | |||
Microsoft Windows 2000 Professional | 9.1 TS1M0 | |||
Microsoft Windows NT Workstation | 9.1 TS1M0 | |||
Microsoft Windows Server 2003 Datacenter Edition | 9.1 TS1M0 | |||
Microsoft Windows Server 2003 Enterprise Edition | 9.1 TS1M0 | |||
Microsoft Windows Server 2003 Standard Edition | 9.1 TS1M0 | |||
Microsoft Windows XP Professional | 9.1 TS1M0 | |||
64-bit Enabled AIX | 9.1 TS1M0 | 9.2 TS2M3 | ||
64-bit Enabled HP-UX | 9.1 TS1M0 | 9.2 TS2M3 | ||
64-bit Enabled Solaris | 9.1 TS1M0 | 9.2 TS2M3 | ||
HP-UX IPF | 9.1 TS1M0 | 9.2 TS2M3 | ||
Linux | 9.1 TS1M0 | 9.2 TS2M3 | ||
OpenVMS Alpha | 9.1 TS1M0 | 9.2 TS2M3 | ||
Tru64 UNIX | 9.1 TS1M0 | 9.2 TS2M3 |