The following error occurs when you run a database COMMIT action against a non-logging Informix IDS database:
INFORMIX: ENTER SQLEndTran 2 0x00000000002a59a8 0 INFORMIX: EXIT SQLEndTran with return code -1 (SQL_ERROR) 2 0x00000000002a59a8 0 ERROR: Informix COMMIT Error: [Informix][Informix ODBC Driver] Unspecified System Error = -11092.
For non-logging databases, neither the COMMIT nor the ROLLBACK action are available.
Select the Hot Fix tab in this note to access the hot fix for this issue.
Product Family | Product | System | SAS Release | |
Reported | Fixed* | |||
SAS System | SAS/ACCESS Interface to Informix | 64-bit Enabled AIX | 9.1 TS1M3 SP4 | |
64-bit Enabled HP-UX | 9.1 TS1M3 SP4 | |||
64-bit Enabled Solaris | 9.1 TS1M3 SP4 | |||
HP-UX IPF | 9.1 TS1M3 SP4 | |||
Linux on Itanium | 9.1 TS1M3 SP4 | |||
Tru64 UNIX | 9.1 TS1M3 SP4 |