Problem Note 31908: "ERROR: Bridge protocol engine socket access method was unable to connect an outcall socket..." occurs in the METALIB procedure
If you run PROC METALIB to connect to a server that has a long DNS host name (longer than 40 characters), PROC METALIB will fail with an error similar to the following:
ERROR: Bridge protocol engine socket access method was unable to connect an outcall
socket to longtruncatedmetadataserverhostnamexxxxx:8561, error = 0 (An unexpected error has occurred.)
In this message, 'longtruncatedmetadataserverhostnamexxxxx' represents the first 40 characters of your metadata server host name. The error occurs because PROC METALIB truncates the host name to 40 characters and is unable to locate the machine.
To circumvent the problem, specify the metadata server IP address instead of the DNS machine name in the METASERVER= option.
Operating System and Release Information
| SAS System | SAS Metadata Server | z/OS | 9.1 TS1M3 SP4 | |
| Microsoft® Windows® for 64-Bit Itanium-based Systems | 9.1 TS1M3 SP4 | |
| Microsoft Windows Server 2003 Datacenter 64-bit Edition | 9.1 TS1M3 SP4 | |
| Microsoft Windows Server 2003 Enterprise 64-bit Edition | 9.1 TS1M3 SP4 | |
| Microsoft Windows XP 64-bit Edition | 9.1 TS1M3 SP4 | |
| Microsoft Windows 2000 Advanced Server | 9.1 TS1M3 SP4 | |
| Microsoft Windows 2000 Datacenter Server | 9.1 TS1M3 SP4 | |
| Microsoft Windows 2000 Server | 9.1 TS1M3 SP4 | |
| Microsoft Windows 2000 Professional | 9.1 TS1M3 SP4 | |
| Microsoft Windows NT Workstation | 9.1 TS1M3 SP4 | |
| Microsoft Windows Server 2003 Datacenter Edition | 9.1 TS1M3 SP4 | |
| Microsoft Windows Server 2003 Enterprise Edition | 9.1 TS1M3 SP4 | |
| Microsoft Windows Server 2003 Standard Edition | 9.1 TS1M3 SP4 | |
| Microsoft Windows XP Professional | 9.1 TS1M3 SP4 | |
| 64-bit Enabled AIX | 9.1 TS1M3 SP4 | |
| 64-bit Enabled HP-UX | 9.1 TS1M3 SP4 | |
| 64-bit Enabled Solaris | 9.1 TS1M3 SP4 | |
| HP-UX IPF | 9.1 TS1M3 SP4 | |
| Linux | 9.1 TS1M3 SP4 | |
| Linux on Itanium | 9.1 TS1M3 SP4 | |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
PROC METALIB produces "ERROR: Bridge protocol engine socket access method was unable to connect an outcall socket to longtruncatedmetadataserverhostnamexxxxx:8561, error = 0
(An unexpected error has occurred.)" when the metadata server host name exceeds 40 characters.
| Type: | Problem Note |
| Priority: | medium |
| Date Modified: | 2008-07-08 14:41:02 |
| Date Created: | 2008-04-28 15:40:42 |