SUPPORT / SAMPLES & SAS NOTES
 

Support

Problem Note 31400: Resetting system time backwards causes negative "real time" value in STIMER output

DetailsHotfixAboutRate It

If the system time is set backwards to a negative value while a SAS DATA step or procedure is running, the "real time" value reported in the SAS log will be negative.

When this situation occurs, the real time value is reported as a very large number, as this example shows:

  1? data; x=1; run;

NOTE: The data set WORK.DATA1 has 1 observations and 1 variables.
NOTE: DATA statement used (Total process time):
      real time           5124095575644:11:23.65
      cpu time            0.04 seconds

On HP Itanium systems, a Domain error occurs.

Beginning with SAS 9.2 (9.2 TS1M0), the same situation will instead produce the following output:

  1? data; x=1; run;
  
NOTE: The data set WORK.DATA1 has 1 observations and 1 variables.
NOTE: DATA statement used (Total process time):
      real time           Unknown due to possible time adjustment
      cpu time            0.04 seconds


Operating System and Release Information

Product FamilyProductSystemSAS Release
ReportedFixed*
SAS SystemN/AMicrosoft® Windows® for 64-Bit Itanium-based Systems9.1 TS1M3 SP19.2 TS1M0
Microsoft Windows Server 2003 Datacenter 64-bit Edition9.1 TS1M3 SP19.2 TS1M0
Microsoft Windows Server 2003 Enterprise 64-bit Edition9.1 TS1M3 SP19.2 TS1M0
Microsoft Windows XP 64-bit Edition9.1 TS1M3 SP19.2 TS1M0
Microsoft® Windows® for x649.1 TS1M3 SP19.2 TS1M0
Microsoft Windows 2000 Advanced Server9.1 TS1M3 SP19.2 TS1M0
Microsoft Windows 2000 Datacenter Server9.1 TS1M3 SP19.2 TS1M0
Microsoft Windows 2000 Server9.1 TS1M3 SP19.2 TS1M0
Microsoft Windows 2000 Professional9.1 TS1M3 SP19.2 TS1M0
Microsoft Windows NT Workstation9.1 TS1M3 SP1
Microsoft Windows Server 2003 Datacenter Edition9.1 TS1M3 SP19.2 TS1M0
Microsoft Windows Server 2003 Enterprise Edition9.1 TS1M3 SP19.2 TS1M0
Microsoft Windows Server 2003 Standard Edition9.1 TS1M3 SP19.2 TS1M0
Microsoft Windows XP Professional9.1 TS1M3 SP19.2 TS1M0
Windows Vista9.1 TS1M3 SP19.2 TS1M0
64-bit Enabled AIX9.1 TS1M3 SP19.2 TS1M0
64-bit Enabled HP-UX9.1 TS1M3 SP19.2 TS1M0
64-bit Enabled Solaris9.1 TS1M3 SP19.2 TS1M0
AIX9.1 TS1M3 SP19.2 TS1M0
HP-UX9.1 TS1M3 SP19.2 TS1M0
HP-UX IPF9.1 TS1M3 SP19.2 TS1M0
Linux9.1 TS1M3 SP19.2 TS1M0
Linux on Itanium9.1 TS1M3 SP19.2 TS1M0
Solaris for x649.1 TS1M3 SP19.2 TS1M0
Tru64 UNIX9.1 TS1M3 SP19.2 TS1M0
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.